INSTRUCTION MANUAL
FOR
MICROCOMPUTER BASED
TEMPERATURE INDICATING CONTROLLER
FCR-13A
Thank you for your purchase of our Microcomputer based Temperature Indicating Controller
FCR-13A.
This manual contains instructions for the mounting, functions, operations and notes when
operating the FCR-13A.
For your confirmation of the model and specifications of the units, peruse and make sure you
have understood this instruction manual before starting operation.
To prevent accidents arising from the use of this controller, please ensure the operator
using it receives this manual.
1

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Shinko FCR-13A-R/M and is the answer not in the manual?

Shinko FCR-13A-R/M Specifications

General IconGeneral
BrandShinko
ModelFCR-13A-R/M
CategoryTemperature Controller
LanguageEnglish

Summary

Setup Procedures

3.1 Internal Assembly Removal

Provides instructions on how to safely remove the internal assembly of the FCR-13A controller from its case.

3.2 Switch Settings

Guides users through configuring the controller using DIP and rotary switches for various functions.

3.3 Internal Assembly Insertion

Describes the correct procedure for reinserting the internal assembly into the FCR-13A controller case.

Operations

4.3 Main Setting Mode

Details how to enter and adjust the main control setting value for the FCR-13A controller.

4.4 Sub Setting Mode

Describes how to access and modify secondary setting parameters for the FCR-13A controller.

4.7 Program Mode Operation

Explains how to set up and run programmed control sequences on the FCR-13A controller.

Setting Value Memory Function

Setting Value Memory Operation

Explains how to memorize, select, and register setting values using the memory function.

Running the Controller

6.2 As a Program Controller

Details the procedure for operating the FCR-13A as a simplified program controller.

Control Actions

8.1 Fuzzy Self-Tuning

Explains the function and benefits of automatic PID value adjustment using fuzzy logic.

8.3 PID Auto-Tuning

Describes the controller's process for automatically determining optimal PID parameters.

Mounting to Control Panel

Wiring Connection

11.1 Terminal Arrangement

Illustrates the layout and function of each terminal on the FCR-13A controller's connection block.

Specifications

Troubleshooting Guide

PV Display Indication Issues

Helps diagnose and resolve problems indicated by abnormal PV display readings or no indication.

Key Operation and Control Issues

Addresses problems related to setting mode selection, value changes, and control start failures.