SiAECOSYS V2
13
2.1Parameters setting for sports mode(S gear)
2.2.1 Bus bar current setting: According to the controller type current corresponding to the selection,
absolutely no over current is allowed.
VOLTAGE
MODEL
EM-30
S
EM-50
EM-50S
EM-100
EM-100S
EM-150
EM-150S
EM-200
EM-300
48-60V
35A
50A
55A
100A
----
200A
----
320A
550A
72V
35A
50A
55A
100A
150A
200A
250A
320A
550A
1. NO/YES
2. Adjustable exit time
Maximum speed
of corresponding
motor after
landing
Three speed percentage,
landing maximum speed
setting value is 100%
Change not allowed
Change
not
allowed
1. Medium speed weak
magnetic field increases
medium speed, range
0-3000
2. Tell the weak magnetic
field to raise the speed of
high gear, with the range
of 0-3000
3. There is no relative
proportion in the
acceleration of the weak
magnetic value. The higher
the weak magnetic value
is, the more the
acceleration is, 100 in each
stage.
High speed flux weakening
Adjust motor jitter
1. The motor shakes more and more to the major
2. The motor does not shake to minor adjustment,
take a reasonable value, range 100-1200, 50 each
stage.
Optional
1. It can be checked. The larger the level is, the
more obvious the starting power is
2. Uncheck for hard start