EasyManuals Logo

Siargo MF4700 Series User Manual

Siargo MF4700 Series
35 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #24 background imageLoading...
Page #24 background image

www.Siargo.com

MF4700UserManual


23
|
Page
Responsetime 0x0017
Write Y
Read Y
Description Meterresponseordatasamplingtime
Valuetype UINT16
Notes
Thedefaultvalueis10(10msec).Optionsare10,20,50,100,and200msec.
Itisrecommendedthatwriteprotectionshouldbeappliedafterthisvalue
ischanged.
Highflowalarm 0x0031~0x0032
Write Y
Read Y
Description Setthehighflowratealarmlimit
Valuetype UINT16
Notes Thesetflowratevalue=[value(0x0031)*65536+value(0x0032)]/1000
Lowflowalarm 0x0033~0x0034
Write Y
Read Y
Description Setthelowflowratealarmlimit
Valuetype UNIT16
Notes Thesetflowratevalue=[value(0x0033)*65536+value(0x0034)]/1000
Offsetreset 0x0027
Write Y
Read N
Description Resetorcalibratetheoffset
Valuetype UINT16,fixedvalue0xAA55
Notes
Sendthefixedvalue0xAA55toregister0x0027.
Pleasemakesurethereisnoflowbeforeexecutingthiscommand.
Writeprotection 0x0014
Write Y
Read N
Description Writeprotectionofaspecificvalue
Valuetype UINT16,afixedvalueofoxAA55
Notes
Thisfunctiondisablesthewriteprotectedregisterandallowsyoutomodify
thecorrespondingregister’svalue.Forexample,tochangethegasconversion
factor,theuserneedstosend0xAA55totheregister0x0016,andthenthe
writefunctionwillbeenabled(writeprotectionisdisabled).Afterthewrite
execution
iscompleted,thefirmwarewillautomaticallyreenablethewrite
protection.