9. Anti Tamper Alarm
The unit uses a LDR (light dependent resistor) as an anti tamper alarm. If the keypad is
removed from the cover then the tamper alarm will operate.
10.Sound and Light indication
Operation Status Red Light
Buzzer
Power on - Bright - Di
Stand by Bright - - -
Press keypad - - - Di
Operation successful - Bright - Di
Operation failed - - - DiDiDi
Enter into programming mode
Bright - -
In the programming mode - - Bright Di
Exit from the programming
mode
Bright - - Di
Open the door - Bright - Di
Alarm Bright - - Alarm
11. Detailed Programming Guide
11.1 User Settings
To enter the programming mode
* Master code #
999999 is the default factory master code
To exit from the programming mode *
Note that to undertake the following programming the master user must be logged in
To change the master code 0 New code # New code #
The master code can be 6 to 8 digits long
Setting the working mode:
Set valid card only users
Set valid card and PIN users
Set valid card or PIN users
3 0 # Entry is by card only
3 1 # Entry is by card and PIN together
3 2 # Entry is by either card or PIN (default)
To add a user in either card or PIN mode, i.e. in the 3 2 # mode. (Default setting)
To add a Pin user
1 User ID number # PIN #