3 Device description
3.1 Device view
Ready
Result
RF
Data
CAN
LNK/ACT
Micro-SD
Micro-SD
Result
RF
Data
CAN
LNK/ACT
Ready
100°
34.4
(1.35)
20.1
(0.79)
20.1
(0.79)
20.1
(0.79)
50 (1.97)
25
(0.98)
25
(0.98)
130.8 (5.15)
130.8 (5.15)
6 x 7.7 (0.30)
137.4 (5.41)
54 (2.13)
18.1
(0.71)
55.3
(2.18)
7
(0.28)
30
(1.18)
25.5
(1.00)
71.9 (2.83)
76.7 (3.02)
71.9
(2.83)
71.9
(2.83)
76.9
(3.03)
69.7
(2.74)
1 2
3
4
5
6
7
8
9
ß à
á
â
ã
113.9 (4.48)
103.3 (4.07)
116 (4.57)
RFU620-101xx
RFU620-105xx
RFU620-104xx
RFU620-101xx
RFU620-105xx
RFU620-104xx
Figure 1: RFU620 (all variants): Structure and dimensions, unit: mm (inch), deci‐
mal separator: period
1
“Power/Serial Data/CAN/I/O” connection (male connector, M12, 17-
pin, A-coded)
2
“Ethernet” connection (female connector, M12, 4-pin, D-coded)
3
“PoE” connection (female connector, M12, 8-pin, X-coded)
4
“Power/Serial data/CAN/I/O” connection (male connector, D-Sub-HD,
15-pin), cable 0.9 m
5
4 x LED, multi-colored (process feedback)
6
7 x LED, multi-colored (status indicator)
7
Optics cover with integrated antenna
8
2 x screw (Torx T8), captive, for side cover
9
Side cover open
ß
“USB” connection (female connector, 5-pin, Micro B type). The USB
interface is only for temporary use as a service interface.
à
Slot for microSD memory card
á
4 x M5 blind tapped holes, 9 mm deep, for alternative mounting of
the device
â
Pressure compensation valve (ventilation element)
ã
2 x M6 blind tapped holes, 6 mm deep for mounting the device
3.2 Status displays
Ready
LNK/ACT
Micro-SD
RF
CAN
Data
Result
Status displays
Advertisement LED Color Status
Ready Lights up Green The device is ready for use.
Lights up Red The device is not ready for use: hardware fault
Flashing Green PROFINET operation (single port):
The LEDs flash cyclically and alternating 4 x red, 1
x green.
•
The device attempts to establish a connec‐
tion to a PLC (IO controller)
– or –
•
During operation: the connection between
the device and the PLC (IO controller) is inter‐
rupted
Flashing Red
Result Lights up Green Read or write was successful
Advertisement LED Color Status
RF Lights up Green The UHF field is switched on.
Lights up Red Fault: integrated antenna or RF part.
Data
2)
Lights up Green Data output via the host interface
CAN
2)
Lights up Orange Data traffic via CAN bus (CAN Rx)
Link/Act Lights up Green Data traffic on the Ethernet interface
microSD Lights up Green The memory card is inserted and ready for opera‐
tion.
•
In this state, the device can either write data
to the memory card or read data on the card.
•
If the LED lights up, however, this does not
indicate that the device is accessing the
card!
Lights up Red The memory card is inserted.
However, the device cannot read data on the
memory card.
Possible causes:
•
The memory card does not contain any data
•
The content is not readable
•
The memory card is defective
Lights up Orange
1)
A function is started with SOPAS ET which
requires a memory card for writing. However, the
memory card is not connected.
1)
Prerequisite: In SOPAS ET, the “SD card required” function has been activated under the
“Service” user level.
2)
RFU620-105 xx (PoE variant): LED without function
Additional indicators for ambient temperatures below –40 °C/-25 °C
Advertisement LED Color Status
Ready Flashing Orange Flashing, frequency 1 Hz.
The device is not ready for use:
•
RFU620-101xx: The internal temperature of
the device is below -40 °C.
•
RFU620-104xx/-105xx: The internal temper‐
ature of the device is below -25 °C
Flashing Green Flashing, frequency 1 Hz.
Warm-up phase of the device:
•
RFU620-101xx: The internal temperature of
the device is between -40 °C and -20 °C.
The device starts up regular operation after a
maximum of 5 min
•
RFU620-104xx/-105xx: The internal temper‐
ature of the device is between -25 °C and
-20 °C. The device starts regular operation
again after about 1 min.
3.3 Memory card (optional accessory)
The device can execute the following functions on the plug-in microSD memory
card:
•
Cloning function: If a MicroSD memory card is present, the device automati‐
cally saves its internal parameter set on the memory card as well. This pro‐
cedure is carried out in the framework of the recommended storing concept
for the device parameter sets. Storing the internal parameter set with the
“permanent” option triggers the cloning function. The function is used,
among other things, to conveniently transfer the parameter set to an
replacement device of the same type in the event of a fault.
•
Data logging: The device continuously records read diagnosis data after the
first manual start, e.g. via SOPAS ET. If the function is permanently set, the
device automatically resumes recording after a restart.
•
Alternatively, with 4Dpro sensors (RFU620-101xx and RFU620-104xx), the
optional CMC600 parameter memory module can also be used as an exter‐
nal storage medium for the cloning function. The parameter memory module
can be used in the optional connection module, e.g. CDB620 or
CDM420-0001. If the device is connected to a data bus via the bus connec‐
tion module CDF600-2xxx, an external storage medium is also available.
NOTE
Recommendation:
Use an empty memory card to save a parameter set for the first time. If nec‐
essary, check the contents of the card on the computer using a card reader
and delete if necessary.
The microSD memory card is not included in the scope of delivery.
Only use types approved by SICK to ensure reliable function of the memory card,
see www.sick.com/RFU62x. The memory card has no write protection that can be
activated.
8015928/10XW/2019-12-12/en RFU62x | SICK 2