FIRST CHECK
After the first 50 hours of work change oil in the gear case and check all bolts and nuts tightening.
EVERY 8 HOURS OF WORK
- Grease with AGIP GREASE MU EP2 the rotor support through the lubricating nipples A
(picture 20) of CS, SA, SD, SF and HLV-HLF tillers.
- Grease the cardan shaft spider of every model of tillers.
EVERY 50 HOURS OF WORK
- Check oil level of sump/bevel gear pair (A - picture 21).
- Check oil level of the lateral drive (A - picture 22),
- Check oil level of the rotor support on ST, SM, SP, RG, SHV-SHF-SHE and SM-F tillers (A -
picture 23).
If necessary feed with AGIP ENI BLASIA 150 80W90 oil.
- On HLV-HLF and SHV-SHF-SHE tillers, check oil of their hydraulic system (cap B – picture
24) and of their mast (cap C – picture 24)
If necessary feed with AGIP OSO 68 hydraulic oil.
- Check that all bolts and nuts are strongly tightened, especially the hoes’ ones.
EVERY 500 HOURS OF WORK
- It is necessary to change oil of the group sump/bevel gear pair, of the lateral drive and of the
rotor support (ST, SM, SP, RG, HLV-HLF, SHV-SHF-SHE, SM-F); use only AGIP ENI
BLASIA 150 80W90 oil.
For this kind of maintenance please contact the nearest SICMA authorized repair shop.