PLACEMENT LOCATION AND INSTALLATION
Do not locate the unit in an area that normally has solvent vapors present, such as a spray booth, mixing area or
solvent storage area. The location should be a well ventilated area away from traffic lanes. Most vapors are heavier
than air, do not locate below ground level or in a basement..
Locate the Sidewinder in a designated NO SMOKING, NO SPARKS, NO FLAMES area. Space the unit a
minimum
5 feet from other potential sources of ignition such as electrical receptacles, switches, pilot lights,
contacts, and other similar equipment that can produce sparks. Post the warning sign conspicuously in the
processing area.
Situate away from traffic and allow for recommended clearances to allow sufficient air flow through the condenser,
to allow access to the clean solvent and to not hinder service access (see clearance diagram). Do not install closer
than
16 inches to a vertical surface at the rear of the unit. Leave 48 inches to the right for service access and at
least 30 inches to the left for access to the clean solvent.
The circuitry responds to temperature changes. Select a well ventilated location out of direct sunlight, under cover
and away from any other source of heat. The Sidewinder is designed for use in ambient temperature from 50°F
(10°C) to 95°F (35°) .
Attach securely to the floor using the mounting holes at the base of the unit legs.
The Sidewinder is not intended for outdoor use.
Be sure to post the warning sign conspicuously in the processing area.