KMS-0021
13
2022-02-10
On receipt, the contents of each Remote Control Unit box should be checked for shipping damage
and the manufacturer informed immediately if any damage is evident:
Check the cardboard box for shipping damage.
Major damage must be documented photographically.
Ensure that any damage to the cardboard box is confirmed by the transport company.
2.4 Unpacking
Unpack the Remote Control Unit and the other items
Check delivery for completeness, and
Examine it for damage during transportation.
If the RCU has been stored in a cold environment and is unpacked in a warm environment it is
recommended to wait a minimum of 2 hours before powering up the RCU to avoid causing
condensation to form inside the RCU.
2.5 Storage
CAUTION
Avoid damage to any units during storage damage can
affect subsequent operation
Do not overload any goods by over stacking. Do not place
heavy goods on top of another.
The Remote Control Unit box should be handled with care and protected from water exposure. It
can be stored in its original transport packaging. The storage room should be well ventilated, as
dust-free as possible and dry. It should have a temperature between -20 °C and +50 °C. The relative
humidity should be kept below a level of 80%.
Note
If stored for long periods of time the battery will require re-
charging at least every 6 months. This should be done
using a standard 12 V battery charger. Take care to not
overcharge the battery.