Siemens 6SL3225-0BE33-7AA0 Specifications

General IconGeneral
Control MethodV/f, Vector control
Protection ClassIP20
Storage Temperature-40 to +70 °C
Product TypeInverter
Input Voltage380-480 V AC
Output Voltage0-480 V AC
Communication InterfacePROFINET
Cooling MethodAir-cooled
Relative Humidity5 to 95% (non-condensing)
AltitudeUp to 1000 m above sea level

Summary

Fundamental safety instructions

General safety instructions

Essential safety guidelines for operating electrical devices and machinery, including danger warnings.

Residual risks of power drive systems

Identifies potential hazards and residual risks associated with power drive system components during operation.

Installing/mounting

Installation conditions

Specifies environmental and installation requirements for reliable, disturbance-free inverter operation.

Power losses and air cooling requirements

Details calculation of cooling airflow based on component power losses to prevent overheating.

Mounting the Power Modules

Describes the correct procedure for physically mounting Power Modules, including protection against fire.

Connection

Line and motor connection

Covers the arrangement and connection of line and motor terminals for inverters.

Dimensioning the protective conductor

Provides guidelines on calculating and laying protective conductors to prevent electric shock.

Motor connection

Details how to connect the motor to the inverter, including star and delta connection methods.

EMC-compliant installation

Covers essential rules and methods for ensuring electromagnetic compatibility during installation.

Installing the converter in compliance with EMC rules

Explains rules for cable installation to ensure electromagnetic compatibility.

EMC-compliant cabinet design

Describes how to design control cabinets to minimize electromagnetic interference.

Equipotential bonding

Details grounding measures and high-frequency equipotential bonding for enhanced EMC performance.

Operation, service and maintenance

Maintenance

Outlines routine maintenance tasks such as cleaning, ventilation checks, and terminal tightening.

Technical specifications

Overload capability of the inverter

Defines and explains the inverter's ability to temporarily supply current higher than its rated current.

Cable cross-sections and tightening torques

Specifies recommended cable sizes and screw tightening torques for various connections.

Power-dependent data

Provides detailed power and current data for different inverter models and frame sizes.

Electromagnetic compatibility of the inverter

Defines electromagnetic compatibility, environments, and categories (C1-C4) for inverter installation.

Spare parts and accessories