Quick Startup Guide for
SIMOVERT MASTERDRIVES
6SE70 VC
Vector Control
Section 1: Parameterization of Base Drive
Section 2: Parameterization of Rectifier
Section 3: Simovis Trace Setup Method
Section 4: When Should a Drive be re-Tuned
Question and Answer IconNeed help?

Do you have a question about the Siemens SIMOVERT MASTERDRIVES 6SE70 VC and is the answer not in the manual?

Siemens SIMOVERT MASTERDRIVES 6SE70 VC Specifications

General IconGeneral
Input Voltage380-480V AC
Output Voltage0-480V AC
Control MethodVector Control, V/f Control
Cooling MethodForced Air Cooling
Protection ClassIP20
Enclosure RatingIP20
Model6SE70
Input Frequency50/60 Hz
Output Frequency0-300 Hz
Communication InterfacesProfibus
Protection FeaturesOvercurrent, Overvoltage, Undervoltage, Overtemperature, Short Circuit
Ambient Temperature Range0°C to +40°C
Storage Temperature Range-25 to +70 °C
Relative Humidity5% to 95% non-condensing

Summary

Section 1: Parameterization of Base Drive

1.1 Power Section Definition

Defines the drive's power section configuration.

1.2 Factory Reset

Restores drive parameters to factory default values.

1.3 Basic Start-up

Guides through the initial setup and configuration process.

1.3.1 Volts/Hz without encoder feedback

Basic start-up using Volts/Hz control without encoder.

1.3.2 Volts/Hz with Encoder Feedback

Start-up using Volts/Hz control with encoder feedback.

1.3.3 Vector Control without Encoder Feedback

Start-up using Vector Control without encoder feedback.

1.3.4 Vector Control with Encoder Feedback

Start-up using Vector Control with encoder feedback.

1.4 Drive Control Word

Configuration of the drive's control word for operation.

1.5 Communication Board Configuration

Setup and configuration of communication boards.

Section 2: Parameterization of a Rectifier Unit

2.0 Power Section Definition

Defines the power section for rectifier units.

2.1 Factory Reset

Resets rectifier unit parameters to factory defaults.

2.2 Rectifier or Regen without auto-transformer

Basic start-up for rectifiers without an auto-transformer.

2.3 Regen with auto-transformer

Basic start-up for rectifiers with an auto-transformer.

Section 3: Simovis Trace Setup Method

Load and Launch Simovis Software

Instructions for loading and launching the Simovis software.

Configure Drive and Communication Settings

Setting up the drive connection and communication parameters in Simovis.

Set Record and Trigger Parameters

Configuring trace recording intervals, channels, and trigger conditions.

Execute and Analyze Traces

Steps to start tracing, observe status, and analyze recorded data.

Section 4: When to Re-Tune the Drive

Conditions Meriting Re-tuning

Situations like hardware, physical, or software changes requiring drive re-tuning.