SINAMICS
SINAMICS V10
Operating Instructions
SW version: V 01.63
08/2011
A5E03453178 (this is not an order number)
Introduction
1
Safety notes
2
Description
3
Identification
4
Installation
5
Commissioning
6
Parameter list
7
Troubleshooting
8
Technical data
9
Replacing the fans
A

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Siemens SINAMICS V10 and is the answer not in the manual?

Siemens SINAMICS V10 Specifications

General IconGeneral
Control MethodV/f control
Degree of protectionIP20
Relative Humidity5 % to 95 % (non-condensing)
AltitudeUp to 1000 m above sea level without derating
Frequency50 Hz / 60 Hz
ProtectionOvercurrent, overvoltage, undervoltage, overload, short circuit, ground fault
CommunicationRS485
Operating Temperature-10°C to +50°C
Power Range0.37 kW to 4 kW
Storage Temperature+70 °C
Input Voltage1-phase: 200-240V AC, 3-phase: 380-480V AC

Summary

Introduction to SINAMICS V10

Purpose of this Manual

Explains the manual's objective for customers regarding the SINAMICS V10 inverter.

Internet Addresses for SINAMICS V10

Provides links for updated product information and user documentation for the SINAMICS V10.

Technical Support Information

Directs users to contact local distributors for product-related questions and assistance.

Safety Notes and Precautions

General Safety Instructions

General safety instructions for handling the inverter and connected equipment.

Electrical Connection Safety

Safety precautions for electrical connections to the inverter.

Commissioning Safety Notes

Safety notes related to the commissioning phase of the inverter.

Troubleshooting Safety Advice

Safety advice for troubleshooting operations involving the inverter.

Equipment Disposal Guidelines

Guidelines for safe and environmentally compliant disposal of equipment.

Product Description and Features

SINAMICS V10 Inverter Overview

Provides a general overview of the SINAMICS V10 inverters and their capabilities.

Key Features and Characteristics

Lists main characteristics, performance, and protection features of the inverter.

Product Identification and Options

Scope of Delivery Details

Details the components included in the SINAMICS V10 inverter package.

MLFB Order Number Explanation

Explains the structure and meaning of the inverter's MLFB order number.

Available Options and Accessories

Lists available optional components for the inverter system.

Spare Parts Information

Lists available spare parts for the SINAMICS V10 inverter.

Installation Procedures

Mechanical Installation Guide

Covers all aspects of the physical installation of the inverter.

Mounting Orientation and Clearance

Specifies correct mounting orientation and required clearances for ventilation.

Wall Mounting Instructions

Provides instructions and dimensions for mounting the inverter directly onto a wall.

Operator Panel to Cabinet Door Mounting

Details how to detach and mount the operator panel onto a cabinet door.

Electrical Installation Guide

Covers the electrical connection and wiring of the inverter.

PE Terminal Layout

Shows the layout of PE terminals across different frame sizes.

Interface Layouts (Non-PE)

Illustrates the arrangement of various connection interfaces on the inverter.

Inverter to Operator Panel Interfaces

Describes the communication interface between the inverter and its operator panel.

Input/Output Cable Conductor Sizes

Specifies recommended conductor sizes for input and output cables.

I/O Terminal Cable Conductor Sizes

Details conductor sizes for digital and analog I/O connecting cables.

Power Supply and Motor Connections

Explains how to connect the power supply and motor to the inverter.

Commissioning the SINAMICS V10

Typical Connection Modes Overview

Describes various typical wiring configurations for the inverter.

Connection Mode C01: Out-of-box Application

Details the basic out-of-box connection mode for the inverter.

Connection Mode C02

Describes connection mode C02 for LOC/REM control.

Connection Mode C03

Describes connection mode C03 for operator panel and external potentiometer control.

Connection Mode C04

Describes connection mode C04 for external control of start/stop, direction, and speed.

Connection Mode C05

Describes connection mode C05 for combined operator panel and external control.

Connection Mode C06

Describes connection mode C06 for external control of start/stop, direction, and frequency.

Connection Mode C07

Describes connection mode C07 for PLC control.

Connection Mode C08

Describes connection mode C08 for PLC and external signal control.

Connection Mode C09

Describes connection mode C09 for JOG mode control.

Connection Mode C10

Describes connection mode C10 for MOP/feedback control.

Connection Mode C11

Describes connection mode C11 for operator panel speed control.

Application Macros Explained

Explains pre-defined application macros for different motor control scenarios.

Operator Panel Functions Overview

Provides an overview and explanation of the operator panel functions and buttons.

Operator Panel Function Details

Details the function of each label, key, and display on the operator panel.

Operator Panel Data Displays

Explains the different types of data displays shown on the operator panel.

Quick Commissioning Guide

Guides the user through the initial setup and configuration process.

Inverter Status Display

Explains how to view the inverter's operational status.

Overview of Operation Modes

Introduces different operational modes for parameter access and configuration.

Operation Mode 1: Quick Motor Data Setting

Describes the mode for setting essential motor parameters.

Operation Mode 2: Connection Macro Selection

Explains how to select connection macros for specific wiring configurations.

Operation Mode 3: Application Macro Selection

Details how to select pre-defined application macros.

Operation Mode 4: Common Application Macro Parameter Setting

Allows setting parameters specific to common application macros.

Operation Mode 5: Access All Parameters

Provides access to all inverter parameters for reading and setting.

Factory Reset Procedure

Explains how to reset the inverter to its factory default settings.

Parameter Cloning with Operator Panel

Guides on uploading and downloading parameter sets between inverters and the operator panel.

Parameter List and Configuration

Inverter Status Parameters

Lists parameters related to the inverter's current operational status.

Motor Data for Quick Commissioning

Parameters for configuring motor characteristics during initial setup.

Digital I/O Specific Parameters

Parameters related to the configuration of digital inputs and outputs.

Analog I/O Specific Parameters

Parameters for configuring analog inputs and outputs.

Frequency Reference Parameters

Parameters related to setting the frequency reference source.

Control Parameters

Parameters that control the inverter's operational behavior.

Protection Specific Parameters

Parameters for configuring various protection functions.

Other General Parameters

Miscellaneous parameters not covered in other specific groups.

User Defined Parameter Settings

Allows defining a custom set of parameters accessible to the user.

Inverter Overload Reaction Configuration

Configures the inverter's reaction to internal over-temperature.

Rated Motor Current Setting

Sets the nominal motor current from the rating plate.

Digital Input 1 Function Selection

Selects the function for digital input 1.

PI Controller Proportion Gain

Allows setting the proportion gain for the PI controller.

Connection Macro Default Settings

Shows default parameter values based on selected connection macros.

Troubleshooting Faults and Alarms

Acknowledging and Clearing Faults

Steps to acknowledge and clear fault codes displayed by the inverter.

Comprehensive Fault List

Lists fault codes, their possible causes, and diagnostic steps.

Alarm List and Interpretation

Lists and explains alarm codes and their possible causes and remedies.

Technical Data Specifications

SINAMICS V10 Inverter Technical Specs

Detailed technical specifications for the SINAMICS V10 inverter across frame sizes.

Mechanical Data and Dimensions

Provides outline dimensions, weight, and mounting methods.

Environmental Conditions for Operation

Specifies operating and storage environmental conditions.

Ambient Temperature Limits

Details ambient temperature limits for operation and derating.

Protection Class and Standards

Specifies the protection class of the inverter and lists compliance with standards.

Replacing Cooling Fans

Removing Fans from Frame Size B

Step-by-step guide to removing fans from Frame Size B inverters.

Removing Fans from Frame Size C

Step-by-step guide to removing fans from Frame Size C inverters.

Removing Fans from Frame Size D

Step-by-step guide to removing fans from Frame Size D inverters.