Par. No. Name Range Default Unit
P1000 Selection of frequency setpoint 0 - 53 5 --
Selects frequency setpoint source.
Possible settings:
0 No main setpoint -
1 MOP setpoint default value for the remote mode of C02 and
C10
2 Analog setpoint default value for the remote mode of C03~C05
and C07~C09
3 Fixed frequency default value for the remote mode of C06
5 Operator panel default value for C01 and C11 and for the local
mode of C02~C10
12 Analog setpoint + MOP setpoint can be used for the remote mode of C02~C10
and C11 if the function of DI reconfigured
13 Fixed frequency + MOP setpoint can be used for the remote mode of C02~C10
and C11 if the function of DI reconfigured
21 MOP setpoint + Analog setpoint can be used for the remote mode of C02~C10
and C11 if the function of DI reconfigured
23 Fixed frequency + Analog setpoint can be used for the remote mode of C02~C10
and C11 if the function of DI reconfigured
25 operation panel + Analog setpoint can be used for C11 if the function of DI
reconfigured
31 MOP setpoint + Fixed frequency can be used for the remote mode of C02~C10
and C11 if the function of DI reconfigured
32 Analog setpoint + Fixed frequency can be used for the remote mode of C02~C10
and C11 if the function of DI reconfigured
35 operation panel + Fixed frequency can be used for C11 if the function of DI
reconfigured
52 Analog setpoint + operation panel can be used for C11 if the function of DI
reconfigured
53 Fixed frequency + operation panel can be used for C11 if the function of DI
reconfigured
Note:
Default value depends on connection macro selected. See Table 7-11 for details.
For users who are familiar with MM4 serial converters, the value from the operation panel (P1000 = 5) equals
to the USS on COM link of MM serial converters.
P1074 Disabling an additional setpoint 0.0 - 2036.F 0.0 -
Common settings:
P1074 = 722.2 => Digital input 3
Dependency:
Accessible only if P0701 - P0703 = 99 (enabling the use of 722.0 - 722.2)
Parameter list
SINAMICS V10
92 Operating Instructions, 08/2011, A5E03453178 (this is not an order number)