6.3.1 Function overview of operator panel
Table 6-13 Operator panel overview
Legend Meaning Function
Inverter status labels
䖤㸠
ذℶᕙᴎ
䆒㕂䇗䇤
RUN
STOP
WAIT
SETTING
TUNE
ᬙ䱰
᡹䄺
ᴀഄ
䖰⿟
ড䕀
FAULT ALARM
LOCAL
REMOTE
REVERSE
RUN: Inverter is running
STOP: Inverter stops operation
WAIT: Inverter is ready for operation
SETTING: The current frequency value shown is the frequency setpoint;
inverter is confirming the selected connection macro or
application macro.
TUNE: Parameter value editing is allowed
FAULT: Inverter is at fault
ALARM: Inverter alarms
LOCAL: Command source is from the operator panel
REMOTE: Command source is from external terminal
REVERSE: Motor is running in a reverse direction
5-digit, 7-segment LCD -
Parameter data unit indicator Used to indicate the data unit of a specific parameter value.
Parameter data units V: Voltage; A: Ampere; Hz: Hertz; Rpm: Revolutions per minute; kW: Kilowatt;
%: percentage
Inverter status indicator Used to indicate current inverter status.
LOC/REM (Local/Remote) key
䖰⿟
ᴀഄ
LOC/REM
Switch between local and remote control modes
1)
LOC: Motor operation is controlled from the operator panel
REM: Motor operation is controlled from an external signal source
SET key
䆒㕂
SET
Long-press SET till
the next operation
mode appears:
Change-over between the following operation modes
(See section "Quick commissioning (Page 63)" for
details):
1. Quick motor data setting → Inverter status display
2. Connection macro selection → Inverter status display
3. Application macro selection → Inverter status display
4. Inverter status display → Access all the parameters
5. Access all the parameters → Inverter status display
Short-press SET: Change-over between the following operation modes
(Points 1-4 below; See section "Quick commissioning
(Page 63)" for details):
1. Motor data setting → Connection macro selection
2. Connection macro selection → Application macro
selection
3. Access all the parameters → Inverter status display
4. Common application macro specific parameter
setting → Inverter status display
5. Move among digits of a specific settable value
6. Clear the fault code displayed
Commissioning
6.3 Operator panel overview
SINAMICS V10
Operating Instructions, 08/2011, A5E03453178 (this is not an order number) 59