Technical data
9
 
Table 9-1 Technical specifications - SINAMICS V10 inverter
Order no.:
6SL3217-0CE
Frame Size A Frame Size B Frame Size C Frame Size D
15-5 
UA1
17-
5 
UA
1
2
1
-
1
 
U
A
1
2
1
-
5
 
U
A
1
22-2 UA1 23-0 
UA1
24-0 
UA1
25-5 
UA1
27-5 
UA1
31-1 
UA1
31-5 
UA1
31-8 
UA1
32-2 
UA1
Display 
5-digit, 7-segment LCD
Configurable motor 3-ph AC asynchronous squirrel cage motors
Electrical data
Rated motor power (kW) 0.55 0.75 1.1 1.5 2.2 3.0 4.0 5.5 7.5 11 15 18.5 22
Rated input current (A) 1.9 2.4 3.7 5.2 6.5 8.6 11.6 15.6 22.0 32.3 38.5 47.1 56.3
Rated output current (A) 1.7 2.2 3.1 4.1 5.9 7.7 10.2 13.2 18.4 26.0 32.0 38.0 45.0
Output 
current derat-
ings with 
pulse freq. 
chang-es
Pulse freq. Range: 2 to 16 kHz; Default PWM: 4 kHz
The max. continuous output current (A) at different pulse frequencies is shown as below: 
1)
2 kHz 1.7 2.2 3.1 4.1 5.9 7.7 10.2 13.2 18.4 26.0 32.0 38.0 45.0
4 kHz 1.7 2.2 3.1 4.1 5.9 7.7 10.2 13.2 18.4 26.0 32.0 38.0 45.0
6 kHz 1.7 2.2 3.1 4.1 5.9 7.7 10.2 13.2 18.4 26.0 27.2 32.3 38.3
8 kHz 1.7 2.2 2.7 2.7 5.1 5.1 6.7 13.2 13.2 17.9 22.4 26.6 31.5
10 kHz 1.7 2.2 2.7 2.7 5.1 5.1 6.7 13.2 13.2 17.9 19.2 22.8 27.0
12 kHz 1.7 1.6 1.6 1.6 3.6 3.6 4.8 9.6 9.6 13.5 16.0 19.0 23.2
14 kHz 1.7 1.6 1.6 1.6 3.6 3.6 4.8 9.6 9.6 13.5 14.4 17.1 20.3
16 kHz 1.1 1.1 1.1 1.1 2.6 2.6 3.6 7.5 7.5 10.4 12.8 15.2 18.0
Mains operating voltage Rated: 3 AC 400 V (tolerance: - 15 % to + 15 %)
Mains input frequency Rated: 50 Hz (tolerance - 3% to + 3%)
Full frequency range: 48 Hz to 52 Hz
Mains system TNC, TNS, TT or IT systems 
2)
Output frequency 0 Hz to 300 Hz
If output frequency is less than 2 Hz for over 0.5 s, the default switching frequency shall 
be reduced to half of the default value.
Power factor  0.95
Inverter efficiency 96 % to 97 %
Overload capability 150% of the rated output current for 60 s; Cycle time: 300 s
SINAMICS V10