Figure 6-24 Common application macro specific parameter setting 
Parameters available for setting in this mode
P1080, P1082, P1120, P1121, P1210 and P1310
 
 
NOTICE
Parameters available for setting in this mode can also be shown in the "Access all the 
parameters" mode. To easily differentiate, the parameter number shown in the "Common 
application macro specific parameter setting" mode has a dot (.) after "P". 
You can set a parameter value either in this mode or in the "Access all parameters" mode. 
Once the value is set, it will be simultaneously updated in both modes.
 
Parameter setting in "Application macro specific parameter setting" mode
See the second figure in topic "Operation mode ① - Quick motor data setting (Page 66)" for 
parameterization method. 
Button/keys inactive in this mode
The STOP, RUN and LOC/REM keys are inactive in this mode. 
Commissioning 
6.6 Overview of various operation modes
SINAMICS V10
70 Operating Instructions, 08/2011, A5E03453178 (this is not an order number)