Figure 5-15 Power and motor connections
 
 
CAUTION
Ensure that the appropriate fuses with specified current ratings are connected between the 
power supply and the inverter (See table below for the type of recommended SIEMENS fuses 
for different frame sizes. ). For detailed fuse specification, consult your local inverter 
distributor or visit the SIEMENS website concerned.
 
Table 5-9 Types of SIEMENS line fuses (recommended)
Inverter variant Inverter output power rating (kW) Fuse type Fuse current rating (A)
Frame Size A 0.55 3NA3803 10 
0.75 3NA3803 10 
1.1 3NA3803 10 
1.5 3NA3803 10 
Frame Size B 2.2 3NA3805 16
3 3NA3805 16 
4 3NA3807 20 
Frame Size C 5.5 3NA3807 20 
7.5 3NA3810 25 
11 3NA3814 35 
Frame Size D 15 3NA3817 40 
18.5 3NA3820 50 
22 3NA3822 63 
Installation
5.2 Electrical installation
SINAMICS V10