Press OK: 1. Acknowledge fault
2. Loop through motor status data display
3. Confirm the selected connection macro or application 
macro
4. Go from a parameter number into its value setting or 
into its parameters index no. and back
Turn OK clockwise: 1. Go into the next parameter no., connection macro or 
application macro.
2. Accelerate the motor
3. Increase the setpoint
Turn OK 
counterclockwise:
1. Go into the last parameter no., connection macro or 
application macro.
2. Decelerate the motor
3. Decrease the setpoint
1)
The factory default control mode is "LOC". In most cases, "LOC" is used for debugging purpose only.
2)
For the description of OFF1 function, see "Notes on OFF functions" in Chapter 7.
3)
For the description of OFF2 function, see "Notes on OFF functions" in Chapter 7. 
6.3.2 Various data displays
 
Table 6-14 Various data displays
Display Example Meaning Remarks
-8.8.8.8.8 Inverter display is lighted -
- - - - - Inverter initializing -
busy Inverter is confirming the selected 
connection macro or application 
macro, or inverter is busy
-
d xxx Actual DC-link voltage -
C xx Connection macro available for 
selection 
There are 10 connection macros available for 
selection: C01 ... C11.
A xx Application macro available for 
selection
There are 6 application macros available for 
selection : A00 ... A05
Commissioning 
6.3 Operator panel overview
SINAMICS V10
60 Operating Instructions, 08/2011, A5E03453178 (this is not an order number)