Mounting the operator panel to cabinet door
The inverter has a removable operator panel. If necessary, you can remove the operator panel 
from the inverter and mount it to the cabinet door. (See topic "Mounting the operator panel to 
cabinet door (Page 31)" for details.) 
 
5.1.4 Mounting the operator panel to cabinet door
 
Mounting dimensions for door-mounted operator panel
You can detach the operator from inverter body unit and mount it to the cabinet door. This 
provides you with the possibility of remote operator panel operation. 
Figure 5-10 Mounting dimensions (outline dimensions + drill patterns + cut-out dimensions)
Table 5-4 Torques for fixing the operator panel to cabinet door
Holes to be drilled 
in cabinet door
Fixing method Tightening torque
(Nm)
4 4 x M3 preassembled screw and washer assemblies
(screw length: 12 mm)
0.8
 
 
NOTICE
If the screw is damaged during mounting, you can select similar M3 preassembled screws 
and assemblies instead. But, make sure the screw length is between 12 mm and 18 mm. 
 
Installation
5.1 Mechanical installation
SINAMICS V10