Option Variant MLFB (order number)
Door mounting components
The door mounting components include:
● Connecting cable, 3-meter long (1 piece)
● Production Information Sheet (1 piece)
● M3 preassembled screw and washer assemblies 
(4 pieces)
- 6SL3256-0VP00-0VA0
Choke 
4)
Line commutating choke: A line commutating choke is 
required to smooth spike pulses in power voltage, or 
voltage sags generated during the phase change of a 
bridge rectifier circuit; besides, a line commutating 
choke can also used to lower harmonic interference to 
inverter and power supply. If power impedance < 1%, 
a line commutating choke is a must to reduce current 
spikes.
Output choke: An output choke is necessary for 
lowering varying rate of capacity current and voltage 
(dv/dt) if the length of motor cable is longer than 50m 
(shielded) or 100m (unshielded). For the detailed 
information about the length of motor cable, please 
refer to Technical data (Page 115)
Frame size Rated out 
put power
Line commutating 
choke
Output choke
Frame Size A 0.55 kW 6SE6400-3CC00-
2AD3
(6SE6400-3CR00-
2AD3)
6SE6400-3TC0
0-4AD2
0.75 kW 6SE6400-3CC00-
4AD3
(6SE6400-3CR00-
4AD3)
1.1 kW
1.5 kW 6SE6400-3CC00-
6AD3
(6SE6400-3CR00-
6AD3)
Frame Size B 2.2 kW 6SE6400-3CC01-
0BD3
(6SE6400-3CR01-
0BD3)
6SE6400-3TC0
1-0BD3
3.0 kW
4.0 kW 6SE6400-3CC01-
4BD3
(6SE6400-3CR01-
4BD3)
Frame Size C 5.5 kW 6SE6400-3CC02-
2CD3
(6SE6400-3CR02-
2CD3)
6SE6400-3TC0
3-2CD3
7.5 kW
11 kW 6SE6400-3CC03-
5CD3
(6SE6400-3CR03-
5CD3)
Framze Size 
D
15 kW
18.5 kW 6SE6400-3CC04-
4DD0
(6SE6400-3CR04-
4DD0)
6SE6400-3TC0
5-4DD0
22 kW 6SE6400-3TC0
3-8DD0
Operating Instructions 
5)
English version -
2) 
The mounting kit consists of two mating parts. You can well engage both parts when installing.
3)
Only used for Frame Size D
4)
An order number without a bracket indicates that this choke is manufactured by a non-Chinese company, while an order 
number with a bracket indicates that this choke is supplied by a local Chinese company. You can make your selection 
according to your own needs.
Identification
SINAMICS V10
18 Operating Instructions, 08/2011, A5E03453178 (this is not an order number)