26 SIMEAS E50417-K109U-C322-A1
Terminals
Jumper positions: Jumper positions:
load-independent current load-independent voltage
To change the jumper positions, the following instructions must
be observed:
Short circuit the ct’s if required.
To remove lid from case insert a flat screwdriver approx.
0.8 * 3.5 mm with an angle of 45° into one after another of the
locking hooks and twist the screwdriver by approx. 45°.
Make a note of the location if necessary.
Pull the modules half-way out by slightly moving them back and
forth.
Change the jumper positions as required.
Plug the modules back into the device
(position the power supply in the middle slot).
Snap the cover back into its correct position.