SITRANS P
Pressure transmitter
SITRANS P320/P420 with 4 to 20
mA/HART
Compact Operating Instructions
7MF03..-.....-.... (SITRANS P320)
7MF04..-.....-.... (SITRANS P420)
09/2018
A5E38874562-AB
Getting started
1
Introduction
2
Safety instructions
3
Installing/mounting
4
Connecting
5
Commissioning
6
Service and maintenance
7
Technical data
8
Appendix A
A

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Siemens 7MF0360 and is the answer not in the manual?

Siemens 7MF0360 Specifications

General IconGeneral
Product designationSITRANS P DS III
Model7MF0360
Device TypePressure Transmitter
ManufacturerSiemens
Measuring range0 to 400 bar
Pressure Range0 to 400 bar
Output signal4 to 20 mA with HART
Power supply10 to 36 V DC
Housing materialAluminum or Stainless Steel
Protection classIP67
Accuracy±0.075% of span
Process Connection1/2 NPT
Electrical ConnectionM20 x 1.5
Operating Temperature-40 to +85 °C (-40 to +185 °F)
MaterialStainless Steel

Summary

Getting started

1.1 Commissioning the device without display

Step-by-step guide for commissioning the device without a display.

1.2 Commissioning the device with display

Step-by-step guide for commissioning the device with a display.

Safety instructions

3.3 Use in hazardous areas

Details qualifications and precautions for using the device in hazardous areas.

Installingmounting

4.1 Basic safety instructions

Provides fundamental safety guidelines for installation and mounting.

4.1.1 Installation location requirements

Specifies requirements for the physical location where the device is installed.

4.1.2 Proper mounting

Details correct procedures and precautions for mounting the device securely.

Connecting

5.1 Basic safety instructions

Essential safety guidelines to follow before connecting the device.

5.2 Connecting the device

Step-by-step instructions for electrically connecting the device.

Commissioning

6.1 Basic safety instructions

Crucial safety measures to observe before and during commissioning.

6.2 Switching on the supply voltage

Instructions for safely switching on the power supply to the device.

6.3 Commissioning the device

General steps and checks for commissioning the device.

6.5 Differential pressure and flow rate

Procedures for commissioning differential pressure and flow measurements.

Service and maintenance

7.1 Basic safety instructions

Fundamental safety guidelines for performing service and maintenance.

7.3 Maintenance and repair work

Outlines procedures and precautions for maintenance and repair.

7.3.3 Diagnostics messages

Explains how diagnostic messages are signaled and interpreted.

Technical data

8.1 Input

Specifies input ranges and limits for various measurement types.

8.1.1 Gauge pressure

Provides technical data for gauge pressure measurements.

8.1.2 Gauge pressure with front-flush diaphragm

Technical data for gauge pressure measurements with front-flush diaphragm.

8.1.3 Gauge pressure from the differential pressure series

Technical data for gauge pressure from differential pressure series.

8.1.4 Absolute pressure from the gauge pressure series

Technical data for absolute pressure from gauge pressure series.

8.1.5 Absolute pressure with front-flush diaphragm

Technical data for absolute pressure with front-flush diaphragm.

8.1.6 Absolute pressure from the differential pressure series

Technical data for absolute pressure from differential pressure series.

8.1.7 Differential pressure and flow

Technical data for differential pressure and flow measurements.

8.1.8 Level

Technical data for level measurements.

8.2 Measuring accuracy of SITRANS P320

Details the measuring accuracy specifications for SITRANS P320.

8.2.3 Gauge pressure

Provides gauge pressure accuracy data for SITRANS P320.

8.2.4 Gauge pressure from the differential pressure series

Accuracy data for gauge pressure from differential pressure series.

8.3 Measuring accuracy of SITRANS P420

Details the measuring accuracy specifications for SITRANS P420.

8.4 Operating conditions

Details the environmental and operational conditions for the device.

8.5 Vibration resistance

Specifies the device's resistance to vibrations and shocks per standards.

8.6 Construction

Details the physical construction and materials of the device.

8.9 Certificates and approvals

Lists the certifications and approvals obtained by the device.

Related product manuals