USER'S MANUAL
Siemens Industry, Inc.
UMSITRPDS3-1
Rev 10
November 2010
Supersedes Rev 9
SITRANS P, Series DSIII Transmitters
for
Pressure, Differential Pressure,
Flanged Level, and Absolute Pressure
Model 7MF4*33-

Table of Contents

Other manuals for Siemens 7MF4633

Question and Answer IconNeed help?

Do you have a question about the Siemens 7MF4633 and is the answer not in the manual?

Siemens 7MF4633 Specifications

General IconGeneral
Product TypePressure Transmitter
Model7MF4633
ManufacturerSiemens
Communication ProtocolHART
Output Signal4 to 20 mA HART
Power Supply10.5 to 45 V DC
Housing MaterialStainless Steel
Protection ClassIP67
Electrical ConnectionM20 x 1.5 or 1/2 NPT
Operating Temperature-40 to 85 °C
AccuracyTypically ±0.075% of span
Process ConnectionG1/2, 1/2 NPT, others available

Summary

1.0 Introduction

1.4 Configuration

Describes how transmitters are configured before use.

2.0 Model 275 Universal HART Communicator

2.2 Communicator Connections

Details how to connect the HART communicator to a transmitter loop.

3.0 Pre-Installation Test

3.1 Procedure

Outlines the steps for performing a functional test on a test bench.

3.2 Establishing Communication

Describes how to connect and communicate with the transmitter.

3.3 Testing the Transmitter

Details how to perform a self-test on the transmitter.

3.5 Checking Transmitter Output

Describes how to verify the transmitter's analog output.

4.0 Installation

4.3 Pre-Installation Considerations and Calculations

Covers factors and calculations before mechanical and electrical installation.

4.4 Mechanical Installation

Covers physical installation and conduit wiring.

4.5 Mechanical Installation, All Models

Covers enclosure rotation and display orientation.

4.6 Electrical Installation

Details loop wiring for point-to-point and multi-drop networks.

4.7 Hazardous Area Installation

Provides specific installation data for hazardous areas.

5.0 Post-Installation Test

5.2 Installation Review

Verifies correct transmitter installation and specifications.

5.3 Equipment Connection

Shows how to connect equipment for system checkout.

5.4 Verification

Covers communication, error checks, and output verification.

5.5 Transmitter Zero and Shutoff Valve Manipulation

Describes setting transmitter zero and adjusting shutoff valves.

6.0 On-Line Configuration and Operation

6.1 Local Operation and Display

Introduces local display and magnetic pushbuttons.

6.4 Remote Configuration and Operation by HART

Explains operation using the HART Communicator.

7.0 Calibration and Maintenance

7.3 Troubleshooting

Provides guidance for identifying and correcting malfunctions.

7.4 Assembly Removal and Replacement

Details removal and replacement of assemblies.

9.0 Model Designations and Specifications

10.0 Glossary

Configuration

Database downloaded to transmitter for operation.

HART

Protocol for simultaneous analog/digital signaling.

12.0 Appendix B - Hazardous Area Installation

Intrinsically Safe Operation in a Hazardous Area

Covers operation in hazardous areas with intrinsically safe circuits.

Installation in Zone 0

Details requirements for installing in Zone 0 hazardous areas.