EasyManua.ls Logo

Siemens 7MF4633 - Model 7 MF4533, Model Designation

Siemens 7MF4633
222 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Model Designations and Specifications UMSITRPDS3-1
November 2010
9-20
TABLE 9-8 Model 7MF4533, Model Designation
Differential pressure and flow transmitter, two-wire, series DSIII, Model 7MF4533-
-
Measuring cell filling
Silicon oil
Measuring cell cleaning
Standard
1
Span
2.5 to 250 mbar (1.004 to 100.4 InH
2
O)
D
6 to 600 mbar (2.409 to 240.9 InH
2
O)
E
16 to 1600 mbar (6.424 to 642.4 InH
2
O)
F
50 to 5000 mbar (20.08 to 2008 InH
2
O)
G
0.3 to 30 bar (4.35 to 435 psi)
H
Wetted parts materials (stainless steel process flanges)
Seal diaphragm Parts of the measuring cell
Stainless steel Stainless steel
A
Hastelloy Stainless steel
B
Gold Gold
L
Process connection
Female thread 1/4-18 NPT with flange connection
Sealing screw opposite process connection:
- Mounting thread M12 to DIN 19213
1
- Mounting thread 7/16-20 UNF to EN 61518
3
Venting on side of process flanges.
- Mounting thread M12 to DIN 19213
5
- Mounting thread 7/16-20 UNF to EN 61518
7
Non-wetted parts materials
Process flange screws Electronics housing
Stainless steel Die-cast aluminum
2
Stainless steel Stainless steel precision casting
3
Version
Standard version
1
International version, English label inscriptions and documentation in 5 languages on CD
2
Explosion protection
Without
A
With ATEX, type of protection:
Intrinsic safety (EEx ia)
B
Explosion proof (EEx d)
D
Intrinsic safety and explosion-proof enclosure (EEx ia + EEx d)
P
Ex nA/nL (Zone 2)
E
Intrinsic safety, explosion-proof enclosure and dust explosion protection (EEx ia +
EEx d + Zone 1D/2D)
R
With FM + CSA, type of protection: Intrinsic safety and explosion proof (is + xp) PN 360 maximum
N C
Electrical connection / cable entry
Screwed gland PG 13.5; Adapter
A
Screwed gland M20 x 1.5
B
Screwed gland 1/2-14 NPT
C
Han 7D plug (plastic housing) includes mating connector
D
M12 connector (metal)
F
Display
Without (digital indicator hidden, setting: mA)
1
With visible digital indicator
6
With customer specific digital indicator and setting; Order code Y21 or Y22 required.
7
Additional selections and data on next page.