EasyManua.ls Logo

Siemens AC265 - Page 7

Siemens AC265
16 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Siemens Home and Office Communication Devices GmbH & Co. KG
Confidential 7 SHC CC RCT
Version 1.5 J. Junggebauer
X / Y Action Options / description
3 / - PIN Reset Set only system Pin to default (0000)
4 / 1 Write to EEPROM address coded string consists of 15
bytes and holds checksum,
mask, data, offset and segment
4 / 2 Version display Sample display:
"0103200 00000"
12-digit
Meaning:
Variante 2-digit “01”
Version 3-digit "032"
Revision 2-digit "00"
space
User ID 3-digit "000"
Localincrement “00”
All decimal
4 / 3 Ring detection frequency 0 = 20-60 Hz
1 = 15-75 Hz
2 = other factory setting
4 / 4 DP behaviour pulse pause 0 = 1.5 : 1
1 = 2 : 1
4 / 5 CLIP list activated 0 = on
1 = off
4 / 6 Off-hook CLIP activated 0 = off
1 = on
6 / 2 Exception Place and Code
6 / 5 Approval test will stay activated until
power on reset
Read out RFPI, working time counter of base station, SW version of base station:
Precondition:
Line seized, number dialled out, connection is set up for at least 8 seconds
1. RFPI of base station
2. IPUI of current handset
3. Working time counter
4. SW version of base station

Related product manuals