X / Y Action Options / description
3 / - PIN Reset Set only system Pin to default (0000)
4 / 1 Write to EEPROM address coded string consists of 15
bytes and holds checksum,
mask, data, offset and segment
4 / 2 Version display Sample display:
"0103200 00000"
12-digit
Meaning:
Variante 2-digit “01”
Version 3-digit "032"
Revision 2-digit "00"
space
User ID 3-digit "000"
Localincrement “00”
All decimal
4 / 3 Ring detection frequency 0 = 20-60 Hz
1 = 15-75 Hz
2 = other factory setting
4 / 4 DP behaviour pulse pause 0 = 1.5 : 1
1 = 2 : 1
4 / 5 CLIP list activated 0 = on
1 = off
4 / 6 Off-hook CLIP activated 0 = off
1 = on
6 / 2 Exception Place and Code
6 / 5 Approval test will stay activated until
power on reset
Read out RFPI, working time counter of base station, SW version of base station:
Precondition:
Line seized, number dialled out, connection is set up for at least 8 seconds
1. RFPI of base station
2. IPUI of current handset
3. Working time counter
4. SW version of base station