en Installation instructions
38
27.2 Appliance dimensions
You will find the dimensions of the appliance here
27.3 Installation below a worktop
Observe the installation dimensions and the installation
instructions when installing below a worktop.
¡ To ventilate the appliance, the intermediate floor
must have a ventilation cut-out.
¡ The worktop must be secured to the fitted unit.
¡ Observe any available installation instructions for the
hob.
¡ Observe different national installation instructions for
the hob.
27.4 Installation underneath a hob
If the appliance is installed under a hob, the following
minimum dimensions must be adhered to (including
substructure, if applicable).
The minimum worktop thickness a is based on the
required minimum clearance ⁠.
Hob type a raised in mm a flush in mm b in mm
Induction hob 42 43 5
Full-surface induction hob 52 53 5
Gas hob 32 43 5
1
Electric hob 32 35 2
1
Observe different national installation instructions for the hob.