Loading...
Installation and connection en
11
Installation and connection
Installation and connec-
tion
Installation and connection
Scope of delivery
After unpacking all parts, check for
any transport damage and for com-
pleteness of delivery.
If you have any complaints, contact
your dealer or our "after-sales ser-
vice" →Page27.
The delivery consists of the following:
¡ Built-in appliance
¡ Equipment and accessories
1
¡ Installation material
¡ Installation instructions
¡ User manual
¡ Customer service directory
¡ Warranty enclosure
2
¡ Energy label
¡ Information on energy consump-
tion and noises
Installing and connecting the
appliance
Requirement:"The scope of delivery
of the appliance is checked."
→Page11
1. "Observe the criteria for the appli-
ance's installation location."
→Page11
2. Install the appliance according to
the enclosed installation instruc-
tions.
3. "Prepare the appliance for first
use." →Page12
4. "Electrically connect the appli-
ance." →Page12
Criteria for the installation
location
Follow these instructions when in-
stalling your appliance.
WARNING
Risk of explosion!
If the appliance is in a space that is
too small, a leak in the refrigeration
circuit may result in a flammable mix-
ture of gas and air.
Only install the appliance in a
space with a volume of at least
1m
3
per 8g refrigerant. The
volume of refrigerant is indicated
on the rating plate. →"Appliance",
Fig. 1 /
3
, Page14
The weight of the appliance ex works
may be up to 65kg depending on
the model.
The subfloor must be of sufficient sta-
bility to bear the weight of the appli-
ance.
Permitted room temperature
The permitted room temperature de-
pends on the appliance's climate
class.
The climate class can be found on
the rating plate. →"Appliance", Fig.
1 /
3
, Page14
Climate class Permitted room temperat-
ure
SN 10°C to 32°C
N 16°C to 32°C
ST 16°C to 38°C
T 16°C to 43°C
The appliance is fully functional within
the permitted room temperature.
1
Depending on the appliance specifications
2
Not in all countries