en Installation and connection
12
If an appliance with climate class SN
is operated at colder room temperat-
ures, the appliance will not be dam-
aged up to a room temperature of
5°C.
Niche dimensions
Observe the niche dimensions if you
install your appliance in the niche. If
this is not the case, problems may
occur when installing the appliance.
Niche depth
Install the appliance in the recom-
mended niche depth of 560mm.
If the niche depth is smaller, the en-
ergy consumption increases slightly.
The niche depth must be a minimum
550mm.
Niche width
An inside niche width of at least
560mm is required for the appli-
ance.
Side-by-side installation
If you want to install two appliances
side by side, you must maintain a
distance of at least 150mm between
the appliances.
Preparing the appliance for
the first time
1. Remove the informative material.
2. Remove the protective foil and
transit bolts, e.g. remove the ad-
hesive strips and carton.
3. "Clean the appliance for the first
time." →Page21
Connecting the appliance to
the electricity supply
1. Insert the non-heating appliance
plug of the power cable into the
appliance.
2. Insert the mains plug of the appli-
ance's power cable in a socket
nearby.
The connection data of the appli-
ance can be found on the rating
plate. →"Appliance", Fig. 1 /
3
,
Page14
3. Check the mains plug is inserted
properly.
a The appliance is now ready for
use.