en Operating the appliance
8
Automatic mode
Switching on
■ Touch the # symbol.
The fan will start at setting 2.
■ Touch the ! symbol.
The optimum fan setting is set automatically using
an air quality sensor.
Switching off
To switch off automatic mode, touch the ! or #
symbol.
The fan will switch off automatically if the air quality
sensor detects no further change in the air quality in the
room.
Automatic mode can run for a maximum of 4 hours.
Sensor control
In automatic mode, an air quality sensor in the extractor
hood detects the intensity of the cooking and roasting
odours. Depending on the air quality sensor setting, the
fan will switch itself to another fan setting automatically.
Possible sensor settings:
Default sensitivity setting: †
Lowest sensitivity setting: ‹
Highest sensitivity setting: Š
If the sensor controller responds too strongly or not
enough, it can be changed accordingly:
1. With the fan switched off, press and hold the !
symbol for approximately 3 seconds. The setting will
be displayed.
2. Touch the @ or A symbol to change the sensor
controller setting.
3. Take your finger off the ! symbol.
Fan run-on time
Switching on
Touch the x symbol. x will light up on the display
panel.
The fan will run at fan setting 1.
The fan will switch off automatically after approximately
10 minutes.
Switching off
Touch the @ symbol.
This immediately stops the fan run-on.
Saturation display
If the metal grease filters or the activated charcoal filter
are/is saturated, the corresponding symbols flashes
after the appliance is switched off:
■ Metal grease filters: !
■ Activated charcoal filter: "
■ Metal grease filters and activated charcoal filter: !
and "
If you have not yet done so, the metal grease filters
should now be cleaned or the activated charcoal filter
replaced. ~ "Cleaning and maintenance" on page 13
Note: The saturation indicator does not apply for non-
renewable activated charcoal filters that are inserted
downstream of the metal grease filter. These activated
charcoal filters must be replaced twice a year.
The saturation indicators can be reset while they are
flashing. To do this, touch the # and A symbols at the
same time.
Switching over the display for air circulation mode
For air recirculation mode, the electronic controller must
be switched over accordingly:
■ The extractor hood must be connected and switched
off.
■ Touch and hold the # and @ symbols at the same
time until "2" lights up for air recirculation mode
(filters that cannot be regenerated).
■ Touch and hold the # and @ symbols again at the
same time until "3" lights up for air recirculation
mode (filters that can be regenerated).
■ Touch and hold the # and @ symbols again at the
same time until the electronic controller has
switched back to air extraction mode (indicator 1 ).
Audible signal
Switching on
With the fan switched off, touch and hold the # and &
symbols at the same time for approximately 3 seconds.
A signal will sound as an acknowledgement.
When the signal tone is activated, ‚ will be lit.
Switching off
With the fan switched off, touch and hold the # and &
symbols at the same time for approximately 3 seconds.
A signal will sound as an acknowledgement.
When the signal tone is deactivated, ‹ will be lit.