HomeConnect  en
7
6.10 Switching off automatic mode
1
Press ⁠.
a The appliance starts at the previously selected fan
setting.
a The ventilation is automatically ended when the
sensor detects no further change in the room air
quality.
a Automatic mode runs for a maximum of four hours.
6.11 Sensor control
1
In automatic mode, a sensor in the appliance detects
the intensity of the cooking and roasting fumes. De-
pending on the setting of the sensor sensitivity, the op-
timum fan setting is automatically switched on. If the
sensor control system reacts too weakly or too
strongly, the setting for the sensor sensitivity may
change.
¡ Factory setting:3
¡ Lowest setting:1
¡ Highest setting:5
6.12 Setting the sensor control
Requirement:The appliance is switched off.
1.
Press and hold ⁠.
a The setting is displayed after approx. onesecond.
2.
To change the setting, slide your finger over the set-
tings area ⁠.
3.
Release ⁠ to save the setting.
6.13 Resetting the saturation indicator
After cleaning the grease filter or after changing the
odour filter, the saturation indicator can be reset.
Requirements
¡ After the appliance has been switched off, ⁠ ap-
pears in the display for the grease filter.
¡ After the appliance has been switched off, ⁠ ap-
pears in the display for the odour filter.
Slide your finger to the left over the settings area
⁠.
a The saturation indicator is reset.
6.14 Setting the saturation indicator
The saturation indicator must be adjusted depending
on the filter used.
Requirement:The appliance is switched off.
1.
Press and hold ⁠ and ⁠.
To set circulating-air mode (non-regenerative fil-
ter), press ⁠.
To set circulating-air mode (regenerative filter),
press ⁠.
To set air extraction mode, press ⁠.
2.
Release ⁠ and ⁠ to save the setting.
6.15 Switching on the lighting
The lighting can be switched on and off independently
of the ventilation system.
Press ⁠.
6.16 Setting the brightness
Press and hold ⁠ until the required brightness is
reached.
6.17 Switching on the audible signal
Requirement:The appliance is switched off.
Press and hold ⁠ and ⁠ at the same time for ap-
prox. three seconds.
a ⁠ appears on the display.
6.18 Switching off the signal tone
Requirement:The appliance is switched off.
Press and hold ⁠ and ⁠ at the same time for ap-
prox. 3 seconds until a signal sounds.
a ⁠ appears on the display.
7  HomeConnect
This appliance is network-capable. Connecting your ap-
pliance to a mobile device lets you control its functions
via the HomeConnect app, adjust its basic settings
and monitor its operating status.
The HomeConnect services are not available in every
country. The availability of the HomeConnect function
depends on the availability of HomeConnect services
in your country. You can find information about this at:
www.home-connect.com.
The HomeConnect app guides you through the entire
login process. Follow the instructions in the HomeCon-
nect app to configure the settings.
Tips
¡ Please consult the documents supplied by
HomeConnect.
¡ Please also follow the instructions in the HomeCon-
nect app.
Notes
¡ Please note the safety precautions in this instruction
manual and make sure that they are also observed
when operating the appliance via the HomeCon-
nect app.
→"Safety", Page2
¡ Operating the appliance on the appliance itself al-
ways takes priority. During this time it is not possible
to operate the appliance using the HomeConnect
app.
¡ In networked standby mode, the appliance requires
a maximum of2W.
¡ If you need your device's MAC address to connect
to your home network, you can find this next to the
rating plate. →Page11
1
Depending on the appliance specifications