7.3.3 Loudspeaker/Ringer
The internal Loudspeaker (Earpiece) is connected to the voiceband part of the
EGOLD+ (VOICEBAND D1,E2) via the mono audio amplifier inside the ASIC (D361).
Input EPN1_FIL - EPP1_FIL Output to earpiece EPN1 - EPP1
The ringing tones are generated with the loudspeaker too. To activate the ringer, the
signal RINGIN from the EGOLD+ (Miscellaneous,E9) is used