Overview of Alarms 03/2009
NCK alarms
2-24
© Siemens AG, 2009. All Rights Reserved
SINUMERIK 840D sl, 840Di sl, SINAMICS, Diagnostics Manual (DAsl), 03/2009
Remedy: Correct MD30554 $MA_AXCONF_ASSIGN_MASTER_NCU and/or MD10002
$MN_AXCONF_LOGIC_MACHAX_TAB.
Program Con-
tinuation:
Switch control OFF - ON.
4010 Invalid identifier used in machine data %1[%2]
Parameters: %1 = String: MD identifier
%2 = Index: MD array index
Definitions: When determining a name in the NCK tables (arrays) for: machine axes, Euler angles, direction vec-
tors, normal vectors, interpolation parameters and intermediate point coordinates, one of the following
syntax rules for the identifier to be entered has been violated:
- The identifier must be an NC address letter (A, B, C, I, J, K, Q, U, V, W, X, Y, Z), possibly with a
numerical extension (840D: 1-99)
- The identifier must begin with any 2 capital letters but not with $ (reserved for system variables).
- The identifier must not be a keyword of the NC language (e.g. POSA).
Reaction: NC not ready.
Mode group not ready, also effective for single axes
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy: Please inform the authorized personnel/service department. Enter the identifier for user-defined
names with correct syntax in the displayed MD.
- Machine axes: MD10000 $MN_AXCONF_MACHAX_NAME_TAB
- Euler angles: MD10620 $MN_EULER_ANGLE_NAME_TAB
- Normal vectors: MD10630 $MN_NORMAL_VECTOR_NAME_TAB
- Direction vectors: MD10640 $MN_DIR_VECTOR_NAME_TAB
- Interpolation parameters: MD10650 $MN_IPO_PARAM_NAME_TAB
- Intermediate point coordinates: MD10660 $MN_INTERMEDIATE_POINT_NAME_TAB
Program Con-
tinuation:
Switch control OFF - ON.
4011 [Channel %1: ] Invalid identifier used in machine data %2[%3]
Parameters: %1 = Channel number
%2 = String: MD identifier
%3 = Index: MD array index
Definitions: When defining names in the channel-specific tables for geometry axes and channel axes, one of the
following syntax rules for the identifier to be entered has been violated:
- The identifier must be an NC address letter (A, B, C, I, J, K, U, V, W, X, Y, Z), possibly with a numer-
ical extension.
- The identifier must begin with any 2 capital letters but not with $ (reserved for system variables).
- The identifier must not be a keyword of the NC language (e.g. SPOS).
Reaction: NC not ready.
Mode group not ready, also effective for single axes
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy: Please inform the authorized personnel/service department.
Enter the identifier for user-defined names with correct syntax in the displayed MD
- Geometry axes: MD20060 $MC_AXCONF_GEOAX_NAME_TAB
- Channel axes: MD10000 $MN_AXCONF_MACHAX_NAME_TAB
Program Con-
tinuation:
Switch control OFF - ON.