08/2005 Overview of Alarms
2-913
© Siemens AG, 2005. All rights reserved
SINUMERIK 840D sl/840D/840Di/810D Diagnostics Guide (DA), 08/2005 Edition
%2 = Drive number
Definitions: The number of encoder marks of the motor measuring system in the drive MD 5005:
ENC_RESOL_MOTOR (number of encoder marks of the motor measuring system) is
zero or greater than the maximum input limit.
Reactions: - NC not ready.
- The NC switches to follow-up mode.
- Channel not ready.
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
Remedy: Match the number of encoder marks of the motor measuring system in drive MD 5005:
ENC_RESOL_MOTOR (number of encoder marks of the motor measuring system) to the
encoder in use. (Default setting for motor measuring system: (Default setting for motor
measuring system: 2048 incr./rev.).
Program Con-
tinuation:
Switch control OFF - ON.
310709 Axis %1 drive %2 error in piston diameter or piston rod diameter
Parameters: %1 = NC axis number
%2 = Drive number
Definitions: The piston diameter in drive MD 5131: CYLINDER_PISTON_DIAMETER is less than or
equal to zero or the piston rod diameter in drive MD 5132:
CYLINDER_PISTON_ROD_A_DIAMETER is greater than the piston diameter in drive
MD 5131: CYLINDER_PISTON_DIAMETER or the piston rod diameter in drive MD 5133:
CYLINDER_PISTON_ROD_B_DIAMETER is greater than the piston diameter in drive
MD 5131: CYLINDER_PISTON_DIAMETER.
Reactions: - NC not ready.
- The NC switches to follow-up mode.
- Channel not ready.
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
Remedy: Enter a valid piston diameter in drive MD 5131: CYLINDER_PISTON_DIAMETER (0 < D
<= 500mm). or Enter a piston rod diameter in drive MD 5132:
CYLINDER_PISTON_ROD_A_DIAMETER which is less than the piston diameter in drive
MD 5131: CYLINDER_PISTON_DIAMETER or Enter a piston rod diameter in drive MD
5133: CYLINDER_PISTON_ROD_B_DIAMETER which is less than the piston diameter
in drive MD 5131: CYLINDER_PISTON_DIAMETER.
Program Con-
tinuation:
Switch control OFF - ON.
310710 Axis %1 drive %2 distance-coded scale incorrectly parameterized
Parameters: %1 = NC axis number
%2 = Drive number
Definitions: If a distance-coded scale is selected (MD 5011 bit 7=1) a length measuring system must
also be configured (MD 5011 bit 4=1).
Reactions: - Mode group not ready.
- Channel not ready.
- NC Start disable in this channel.
- Interface signals are set.

Other manuals for Siemens MCP 398C

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens MCP 398C and is the answer not in the manual?

Siemens MCP 398C Specifications

General IconGeneral
BrandSiemens
ModelMCP 398C
CategoryControl Systems
LanguageEnglish

Related product manuals