EasyManuals Logo

Siemens MCP 398C Diagnostics Guide

Siemens MCP 398C
1002 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #921 background imageLoading...
Page #921 background image
08/2005 Overview of Alarms
2-921
© Siemens AG, 2005. All rights reserved
SINUMERIK 840D sl/840D/840Di/810D Diagnostics Guide (DA), 08/2005 Edition
- Channel not ready.
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
- Channel not ready.
Remedy: The gradient in the coarse area is calculated as follows:
• Positive quadrant: (MD 5485 - MD 5464) / (MD 5486 -5465)
• Negative quadrant: (MD 5487 - MD 5467) / (MD 5488 - 5468)
Enter a valid combination in the above drive MD.
Program Con-
tinuation:
Clear alarm with the RESET key in all channels. Restart part program.
310773 Axis %1 drive %2 gain at end of saturation area of valve characteristic is less than
or equal to zero
Parameters: %1 = NC axis number
%2 = Drive number
Definitions: The gradient at the end of the saturation area of the valve characteristic is less than or
equal to zero. The saturation area is rounded by a parabola. The parabola has a maxi-
mum in the saturation area and can therefore not be inverted.
Reactions: - NC not ready.
- The NC switches to follow-up mode.
- Channel not ready.
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
- Channel not ready.
Remedy: The gradient at the end of the saturation area is calculated as follows:
• Positive quadrant: 2 * (1.0 - MD 5485) / (1.0 - MD 5486) - (MD 5485 - MD 5464) / (MD
5486 -5465)
• Negative quadrant: 2 * (1.0 - MD 5487) / (1.0 - MD 5488) - (MD 5487 - MD 5467) / (MD
5488 - 5468)
Enter a valid combination in the above drive MD.
Program Con-
tinuation:
Clear alarm with the RESET key in all channels. Restart part program.
310774 Axis %1 drive %2 zero area and knee area of valve characteristic overlap
Parameters: %1 = NC axis number
%2 = Drive number
Definitions: The zero area and the knee area of the valve characteristic overlap.
Reactions: - NC not ready.
- The NC switches to follow-up mode.
- Channel not ready.
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
- Channel not ready.
Remedy: The zero area and the knee area overlap if:

Other manuals for Siemens MCP 398C

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens MCP 398C and is the answer not in the manual?

Siemens MCP 398C Specifications

General IconGeneral
BrandSiemens
ModelMCP 398C
CategoryControl Systems
LanguageEnglish

Related product manuals