Parameter Function Default
P085 Nominal power for motor (kW/hp)
✩✩✩
P086  ● Motor current limit (%) 150
P087 Motor PTC enable 0
P089  ●
Stator resistance (Ω)
✩✩✩
P091  ● Serial link slave address 0
P092  ● Serial link baud rate 6
P093  ● Serial link timeout (seconds) 0
P094  ● Serial link nominal system setpoint
(Hz)
50.00
P095  ● USS compatibility 0
P099  ● Communication adapter type 0
P101  ● Operation for Europe or North America 0
P111 Inverter power rating (kW/hp)
✩✩✩
P112 Inverter type 8
P113 COMBIMASTER model -
P121 Enable/disable RUN button 1
P122 Enable/disable FORWARD/REVERSE
button
1
P123 Enable/disable JOG button 1
P124
Enable/disable ∆ and ∇ buttons
1
P125 Reverse direction inhibit 1
P131 Frequency setpoint (Hz) -
P132 Motor current (A) -
P133 Motor torque (% nominal torque) -
P134 DC link voltage (V) -
P135 Motor RPM -
P137 Output voltage (V) -
P140 Most recent fault code -
P141 Most recent fault code –1 -
P142 Most recent fault code –2 -
P143 Most recent fault code –3 -
P151  ● Green LED function 4
Parameter Function Default
P152  ● Yellow LED function 5
P201 PI closed loop mode 0
P202  ● P gain (%) 1.0
P203  ● I gain (%) 0.00
P205  ● Sample interval (x 25 ms) 1
P206  ● Transducer filtering 0
P207  ● Integral capture range (%) 100
P208 Transducer type 0
P210 Transducer reading (%) -
P211  ● 0% setpoint 0.00
P212  ● 100% setpoint 100.00
P220 PI frequency cut-off 0
P331 Analogue mode 2
P332 Fine adjustment (%) 10
P723 State of digital inputs -
P845
Motor current limt for flying start
(V3.00)
50
P910  ● Local/Remote mode 0
P922 Software version -
P923  ● Equipment system number 0
P930 Most recent fault code -
P931 Most recent warning type -
P944 Reset to factory default settings 0
P971  ● EEPROM storage control 1
P986 Relay Output 0
WARNING
Please refer to the Reference Manual before changing any parameters.