EasyManua.ls Logo

Siemens RDG160TU User Manual

Siemens RDG160TU
23 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
CE1N3181en
2017-11-20
Building Technologies
s
3
181
RDG100
RDG110
RDG110U
RDG100T RDG100T/H
RDG160T
RDG160TU
Wall-mounted room
thermostats with LCD
RDG1..
for fan coil unit applications
for universal applications
for use with compressors in DX-type equipment
RDG100..: Operating voltage AC 230 V, On/Off, 3-positon or PWM control
outputs
RDG110: Operating voltage AC 230 V, On/Off relay (SPDT) outputs
RDG110U: Operating voltage AC/DC 24 V, On/Off relay (SPDT) outputs
RDG100../RDG110..: Output for 1-speed and 3-speed
RDG160T..: Operating voltage AC/DC 24 V, DC 0…10 V or On/Off control
outputs
RDG160T..: Output for 1-speed, 3-speed or ECM fan DC 0...10 V
Operating modes: Comfort, Economy and Protection
Automatic or manual fan speed
3 multifunctional inputs for keycard contact, external sensor, etc
Automatic or manual heating/cooling changeover
Adjustable commissioning and control parameters
Minimum and maximum setpoint limitation
Backlit display
Additional features of RDG100T, RDG160T.., RDG100T/H:
Infrared remote control receiver
Auto Timer mode with 8 programmable timers
Auto timer can be disabled via P02
Auto timer can be disabled via DIP switches (RDG160T..)
Landscape design (RDG100T/H only)
Selectable relay output functions (RDG160T..)

Other manuals for Siemens RDG160TU

Question and Answer IconNeed help?

Do you have a question about the Siemens RDG160TU and is the answer not in the manual?

Siemens RDG160TU Specifications

General IconGeneral
TypeRoom Thermostat
DisplayLCD
Digital Inputs2
Relay Outputs1
IP Protection RatingIP30
Accuracy±0.5 °C
Protection ClassIII
Temperature Range0 to 50 °C
Switching Current4 A
MountingWall
Ambient Temperature0 to 50 °C
Storage Temperature-20 to 70 °C
Relative Humidity≤ 95% (non-condensing)

Summary

Wall-mounted Room Thermostats with LCD

Thermostat Functions

Applications, DIP Setting, and Control Outputs

2-pipe Fan Coil Unit Applications

Details configuration for 2-pipe fan coil systems.

4-pipe Fan Coil Unit Applications

Details configuration for 4-pipe fan coil systems.

2-pipe Fan Coil Unit with Electric Heater

Explains setup for 2-pipe systems with electric heating.

Mounting and Installation Guide

Commissioning Procedure

Technical Data - RDG100/RDG110

Power Supply Specifications

Details electrical voltage and power requirements.

Control Output Specifications

Describes the types and ratings of control outputs.

Input Specifications

Lists available inputs and their functions.

Connection Terminals

RDG100 Connection Diagrams

RDG110 Connection Diagrams

RDG110U Connection Diagrams

RDG160T Connection Diagrams

RDG160TU Connection Diagrams

Related product manuals