Installing the Device
2.5.1Connecting High AC/DC Power
1. Connect the power supply terminal block to the device.
4
1
3
2
1
European-style (Euroblock) Terminal Block
2
Positive/Live (+/L) Terminal
3
Ground Terminal
4
Negative/Neutral (-/N) Terminal
Figure2.5 AC Terminal Block Wiring – European-style (Euroblock) Terminal Block for HIP
Power Supplies
4
5
6
4 1
5
1 6
2
3
1
Not Connected
2
Removable Screw Terminal Block
3
Non-removable Screw Terminal Block
4
Positive/Live (+/L) Terminal
5
Ground Terminal