EasyManua.ls Logo

Siemens RUGGEDCOM RX1524 - Page 23

Siemens RUGGEDCOM RX1524
64 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Installing the Device
2.5.1Connecting High AC/DC Power
6
Negative/Neutral (-/N) Terminal
Figure2.6 AC Terminal Block Wiring – Screw Terminal Block for HI Power Supplies
Note
For secure, reliable connections under severe shock or vibration, use M3.5 ring
lugs with a maximum outer diameter of 7 mm (0.28 in). Make sure no bare
metal is exposed beyond the safety cover.
2. Connect the positive wire from the power source to the positive/live (+/L)
terminal on the terminal block.
3. Connect the negative wire from the power source to the neutral/negative (-/N)
terminal on the terminal block.
4. For screw terminal blocks, install the safety cover.
4
3
2
1
1
Screw
2
Safety Cover
3
Screw Terminal Block
4
RUGGEDCOM RX1524 Device
Figure2.7 Assembling the Safety Cover
5. Using a braided wire or other appropriate grounding wire, connect the ground
terminal to the chassis ground connection.
14
RUGGEDCOM RX1524
Installation Manual, 04/2021, C79000-G8976-1487-02