SCALANCE M874, M876 
Operating Instructions, 06/2015, C79000-G8976-C331-05 
31 
 
 
SUBSTITUTION OF COMPONENTS MAY IMPAIR SUITABILITY FOR CLASS I, DIVISION 
2 OR ZONE 2. 
 
DO NOT OPEN WHEN ENERGIZED. 
 
Safety when connecting up 
Safety notices 
When connecting up the device, keep to the safety notices listed below. 
 
The equipment is designed for operation with Safety Extra-Low Voltage (SELV) by a 
Limited Power Source (LPS). 
This means that only SELV / LPS complying with IEC 60950-1 / EN 60950-1 / VDE 0805-1 
must be connected to the power supply terminals. The power supply unit for the equipment 
power supply must comply with NEC Class 2, as described by the National Electrical Code 
(r) (ANSI / NFPA 70). 
If the equipment is connected to a redundant power supply (two separate power supplies), 
both must meet these requirements.