Description 
  2.5 C-PLUG 
SCALANCE W788-xPRO/RR / SCALANCE W74x-1PRO/RR 
Operating Instructions (Compact), Release 08/2007, A5E00413342-05 
85 
2.5  C-PLUG 
Configuration information on the C-PLUG 
The C-PLUG is used to transfer the configuration of the old device to the new device when a 
device is replaced. When the new device starts up with the C-PLUG, it then continues 
automatically with exactly the same configuration as the old device. One exception to this 
can be the IP configuration if it is set over DHCP and the DHCP server has not been 
reconfigured accordingly. 
Reconfiguration is necessary if you use WDS or redundancy with devices with more than 
one WLAN interface and use the MAC addresses and not the sysNames. These functions 
are then based on the MAC address that inevitably changes if a device is replaced. 
 
  Note 
In terms of the C-PLUG, the SCALANCE W-700 devices work in two modes: 
•  Without C-PLUG 
The device stores the configuration in internal memory. This mode is active when no C-
PLUG is inserted. 
•  With C-PLUG 
The configuration stored on the C-PLUG is displayed over the user interfaces. In this 
mode, the internal memory is neither read nor written. If changes are made to the 
configuration, the device stores the configuration directly on the C-PLUG. This mode is 
active when no C-PLUG is inserted. As soon as the device is started with a C-PLUG 
inserted, the SCALANCE W-700 starts up with the configuration data on the C-PLUG. 
 
2.6  Reset button 
Functions of the reset button 
The reset button is on the rear of the device below the sealing screw directly beside the C-
PLUG and has several functions: 
●  Restart of the device 
To restart the device, press the Reset button. 
●  Loading new firmware 
If the normal procedure with the Load & Save menu of Web Based Management does not 
work, the reset button can be used to load new firmware. This situation can occur if there 
was a power outage during the normal firmware update. 
●  Restoring the default parameters (factory defaults) 
●  Adopting the configuration data from the PRESET PLUG.