Connecting up   
4.2 Lightning protection, power supply, and grounding 
  SCALANCE W788-xPRO/RR / SCALANCE W74x-1PRO/RR 
90  Operating Instructions (Compact), Release 08/2007, A5E00413342-05 
4.2  Lightning protection, power supply, and grounding 
Notes on lightning protection 
 
WARNING 
 
Danger due to lightning strikes 
Antennas installed outdoors must be within the area covered by a lightning protection 
system. Make sure that all conducting systems entering from outdoors can be protected by 
a lightning protection potential equalization system. 
When implementing your lightning protection concept, make sure you adhere to the VDE 
0182 or IEC 62305 standard. 
 
A suitable lightning conductor is available in the range of accessories of SIMATIC NET 
Industrial WLAN:  
Lightning protector LP798-1N (order no. 6GK5798-2LP00-2AA6) 
 
WARNING 
 
Danger due to lightning strikes 
Installing this lightning protector between an antenna and a SCALANCE W-700 is not 
adequate protection against a lightning strike. The LP798-1N lightening protector only 
works within the framework of a comprehensive lightning protection concept. If you have 
questions, ask a qualified specialist company. 
 
  Note 
The requirements of EN61000-4-5, surge immunity tests on power supply lines, are met only 
when a Blitzductor is used with 12 - 24 V DC and 48 V DC: 
12 - 24 V DC: VT AD 24V type no. 918 402  
48 V DC: Type no. 919 545 and 919 506 (holder) 
Manufacturer: DEHN+SÖHNE GmbH+Co.KG, Hans Dehn Str. 1, Postfach 1640, D-92306 
Neumarkt, Germany