Description 
  2.3 Different properties for devices with other hardware 
SCALANCE W788-xPRO/RR / SCALANCE W74x-1PRO/RR 
Operating Instructions (Compact), Release 08/2007, A5E00413342-05 
79 
Assignment of the power wires with a hybrid cable 2 x 2 + 4 x 0.34 
 
Wire color code (standard)  Brown  Brown  Black  Black 
Function  24 V  24 V  Ground  Ground 
Power supply insert module  1  2  3  4 
 
Assignment of the power wires with an IE FC TP standard cable 4 x 2 GP 
 
Wire color code (standard)  White / blue 
(1)
  Blue  White / brown 
(1)
 Brown 
Function  24 V  24 V  Ground  Ground 
Power supply insert module  1  2  3  4 
(1)
 White wire of the pair 
Earthing 
 
CAUTION 
 
Damage to the device due to potential differences 
There must be no potential difference between the following parts otherwise there is a risk 
that the device will be destroyed: 
•  Ground potential of the power supply and ground potential of the antenna ground. 
•  Ground potential of the power supply and a grounded housing. 
•  Ground potential of the power supply and the ground potential of the device connected 
to Industrial Ethernet (for example PC, AS-300, AS-400 etc.). 
Connect both grounds to the same foundation earth or use an equipotential bonding cable.