Technical Specifications
7.1 Technical specifications
SCALANCE X-200
Compact Operating Instructions, 12/2010, A5E00813159-11
101
Device type
SCALANCE
Degree of protection MTBF
X206-1 IP30 78.71 years
XF206-1 IP20 43.52 years
X212-2 IP30 51.18 years
X204-2LD IP30 74.64 years
X206-1LD IP30 78.71 years
X212-2LD IP30 51.18 years
X202-2IRT IP30 70.90 years
X204IRT IP30 80.58 years
XF204IRT IP20 80.58 years
X204 IRT PRO IP67 98.55 years
X202-2P IRT PRO IP67 84.99 years
X201-3P IRT PRO IP67 84.99 years
X202-2P IRT IP30 83.72 years
X201-3P IRT IP30 78.03 years
X200-4P IRT IP30 73.06 years
Table 7- 9 Switching properties
Device type
SCALANCE
Max. number of
learnable addresses
Aging time Switching technique Latency
X-200 8000 30 s Store and forward 5 μs
XF-200 8000 30 s Store and forward 5 μs
X-200IRT 4096 30 s (configurable) Store and forward / cut through < 5 μs
XF204IRT 4096 30 s (configurable) Store and forward / cut through < 5 μs
Table 7- 10 Permitted ambient conditions
Device type
SCALANCE
Operating temperature Storage/transport
temperature
Relative humidity in
operation
Operating altitude at max. xx°C
ambient temperature
XF204 *) -40 °C to +60 °C -40 °C to +70 °C ‹ 95 %
(no condensation)
2000 m at max. 56 °C
3000 m at max. 50 °C
X208 -40 °C to +60 °C -40 °C to +70 °C ‹ 95 %
(no condensation)
2000 m at max. 56 °C
3000 m at max. 50 °C
XF208 *) -40 °C to +60 °C -40 °C to +70 °C ‹ 95 %
(no condensation)
2000 m at max. 56 °C
3000 m at max. 50 °C
X216 -40 °C to +60 °C -40 °C to +70 °C ‹ 95 %
(no condensation)
2000 m at max. 56 °C
3000 m at max. 50 °C
X224 -40 °C to +60 °C -40 °C to +70 °C ‹ 95 %
(no condensation)
2000 m at max. 56 °C
3000 m at max. 50 °C
X204-2 -40 °C to +60 °C -40 °C to +70 °C ‹ 95 %
(no condensation)
2000 m at max. 56 °C
3000 m at max. 50 °C
XF204-2 *) -40 °C to +60 °C -40 °C to +70 °C ‹ 95 %
(no condensation)
2000 m at max. 56 °C
3000 m at max. 50 °C
X206-1 -40 °C to +60 °C -40 °C to +70 °C ‹ 95 %
(no condensation)
2000 m at max. 56 °C
3000 m at max. 50 °C

Questions and Answers: