Technical Specifications
7.1 Technical specifications
SCALANCE X-200
102 Compact Operating Instructions, 12/2010, A5E00813159-11
Device type
SCALANCE
Operating temperature Storage/transport
temperature
Relative humidity in
operation
Operating altitude at max. xx°C
ambient temperature
XF206-1 *) -40 °C to +60 °C -40 °C to +70 °C ‹ 95 %
(no condensation)
2000 m at max. 56 °C
3000 m at max. 50 °C
X212-2 -40 °C to +60 °C -40 °C to +70 °C ‹ 95 %
(no condensation)
2000 m at max. 56 °C
3000 m at max. 50 °C
X204-2LD -40 °C to +60 °C -40 °C to +70 °C ‹ 95 %
(no condensation)
2000 m at max. 56 °C
3000 m at max. 50 °C
X206-1LD -40 °C to +60 °C -40 °C to +70 °C ‹ 95 %
(no condensation)
2000 m at max. 56 °C
3000 m at max. 50 °C
X212-2LD -40 °C to +60 °C -40 °C to +70 °C ‹ 95 %
(no condensation)
2000 m at max. 56 °C
3000 m at max. 50 °C
X202-2IRT -40 °C to +60 °C -40 °C to +70 °C ‹ 95 %
(no condensation)
2000 m at max. 56 °C
3000 m at max. 50 °C
X204IRT -40 °C to +70 °C -40 °C to +60 °C ‹ 95 %
(no condensation)
2000 m at max. 56 °C
3000 m at max. 50 °C
XF204IRT *) -40 °C to +60 °C -40 °C to +60 °C ‹ 95 %
(no condensation)
2000 m at max. 56 °C
3000 m at max. 50 °C
X204 IRT PRO -25 °C to +70 °C -40 °C to +70 °C ‹ 95 %
(no condensation)
2000 m at max. 56 °C
3000 m at max. 50 °C
X202-2P IRT
PRO
-25 °C to +60 °C -40 °C to +70 °C ‹ 95 %
(no condensation)
2000 m at max. 56 °C
3000 m at max. 50 °C
X201-3P IRT
PRO
-25 °C to +60 °C -40 °C to +70 °C ‹ 95 %
(no condensation)
2000 m at max. 56 °C
3000 m at max. 50 °C
X202-2P IRT -25 °C to +60 °C -40 °C to +70 °C ‹ 95 %
(no condensation)
2000 m at max. 56 °C
3000 m at max. 50 °C
X201-3P IRT -25 °C to +50 °C -40 °C to +70 °C ‹ 95 %
(no condensation)
2000 m at max. 45 °C
3000 m at max. 40 °C
X200-4P IRT -25 °C to +40 °C -40 °C to +70 °C ‹ 95 %
(no condensation)
2000 m at max. 35 °C
3000 m at max. 30 °C
Note
*) Remember the installation orientation of the IE Switch XF-200
if the IE Switch XF-200 is installed horizontally, a maximum ambient temperature of +40 °C
is permitted.