| Rated Power | 2.2 kW |
|---|---|
| Output Power | 2.2 kW |
| Input Voltage | 3-phase 380-480V AC |
| Frequency | 50/60 Hz |
| Protection Class | IP20 |
| Operating Temperature | -10°C to +50°C |
| Cooling Method | Fan Cooling |
| Relative Humidity | 95% (non-condensing) |
| Altitude | Up to 1000 m |
| Vibration | 5.9 m/s² |
Provides general warnings, preventive measures, and danger warnings applicable to all SED2 VSD work.
Outlines safety requirements for authorized personnel during commissioning of the VSD.
Details safety precautions for operating the SED2 variable speed drives, including emergency stop.
Specifies safety procedures and authorized personnel for repairing the VSD.
Details best practices for wiring to minimize electromagnetic interference, including cable routing and grounding.
Provides critical safety instructions and checks for connecting mains and motor power.
General warnings for authorized personnel regarding high voltages and safe operation during commissioning.
Provides a checklist of essential checks before starting the VSD and motor operation.
Explains the function of each button on the BOP and AOP for operation and parameterization.
Details different modes for commissioning the VSD, including quick commissioning.
Provides a flowchart overview of the commissioning process using BOP or AOP.
Explains the quick commissioning procedure using parameters P0010 and P0003 for motor setup.
Guides on how to parameterize the VSD using motor data from the rating plate.
Describes commissioning procedures using the BOP or AOP, including default settings.
Describes the step-by-step process for changing parameters using the BOP or AOP interface.
Details the procedure for resetting SED2 parameters to their factory default values.
Provides steps for basic motor operation using the BOP, including start, stop, and speed control.
Introduces system parameters and methods for accessing and changing them.
Explains how to change parameters via BOP, AOP, or serial interface, and parameter identification.
Details methods for accessing and filtering VSD parameters based on access level and function.
Describes the four access levels (Standard, Extended, Expert) for parameter access and their dependency on P0003.
Explains how to limit parameter visibility and access using the P0004 filter function.
Covers fundamental functions including digital and analog inputs/outputs and their programming.
Details the six digital input channels, their programming, and available settings.
Explains the use of analog inputs for signals and their conversion via A/D converters.
Defines the type of analog input and enables monitoring, matching DIP switch settings.
Defines input scaling parameters (x1, y1, x2, y2) for analog inputs using a curve.
Explains analog outputs for displaying status variables like frequency, voltage, or current.
Selects which physical status variable (frequency, voltage, current) is output as an analog signal.
Defines output characteristic scaling (x1, y1, x2, y2) for DAC outputs.
Sets the source for the frequency setpoint, allowing selection from terminals, BOP, or serial interface.
Selects the source for command signals (ON/OFF, Reverse) from terminals, BOP, or serial communication.
Describes the PID controller for temperature, pressure, and speed control in HVAC applications.
Guides on setting up the PID controller for fixed or external setpoints and analog input configuration.
Explains the belt failure detection function based on torque/frequency comparison.
Details setting frequency limits and reaction parameters for belt failure detection.
Provides guidance on diagnosing issues using the operator panel, including common motor start problems.
Lists VSD error codes, their causes, diagnosis/remedy, and reaction type.
Details VSD error codes (F0001-F0452) with causes, diagnosis, remedies, and reactions.
Lists VSD warning codes (A0501-A0924) with causes, diagnosis, remedies, and reactions.