KTP700F Mobile Arctic - Quick Install Guide © Siemens AG 2020. All rights reserved Siemens AG Division Digital Factory
2 A5E49083421-AA, 02/2020 Postfach 48 48, 90026 NÜRNBERG, GERMANY
SIMATIC HMI
KTP700F Mobile Arctic - Quick Install Guide
Product Information
A5E49083421
Validity
This product information is valid for the HMI device SIMATIC HMI KTP700F Mobile Arctic with the article numbers listed under "Required system components".
This product information describes the general commissioning of the HMI device. Before setting up and commissioning the system, refer to the "Mobile Panels 2nd Generation" operating
instructions for a description of the safety functions of fail-safe HMI devices and other information. You can find the operating instructions on the supplied DVD and on the Internet
(https://support.industry.siemens.com/cs/ww/en/view/109477845
).
Required system components
HMI Device KTP700F Mobile Arctic
KTP Mobile connecting cable
Connection Box compact or Connection Box advanced
Article numbers 6AV2145-6GB06-0AA0 Article numbers 6AV2181-5AF..-0AX0 Article numbers 6AV2125-2AE03-0AX0 oder 6AV2125-2AE23-0AX0
You can find ordering information for accessories on the Internet (https://mall.industry.siemens.com).
Installing connection boxes
Use the product information provided for the connection box.
1.
Mount the connection box.
2.
Set a unique box ID.
3.
Connect the protective conductor.
4.
If you are installing a hard-wired F-system, connect the cables for the
EMERGENCY STOP button and acknowledgment button with your processing unit.
5.
Connect the connection box with PROFINET (LAN).
6.
Connect the cables for the power supply.
Connecting the connecting cable to the Mobile Panel
1.
Insert a
SIMATIC HMI
memory card
if required.
2.
Connect the
connector of the
cable to the X1 and
X80 interfaces in
the connection
c
ompartment.
Close the connection
compartment.
Tighten
the corresponding
screws using a torque
of 0.2
Nm.
Connecting the Mobile Panel
Repeat steps 1 to 3 for each connection box you operate with the fail-safe HMI device.
Transferring a project
Note
Configure the PROFIsafe
address of the HMI device in the Control Panel before the project transfer. The PROFIsafe address in the Control Panel must c
orrespond to the PROFIsafe address
of the HMI device in the project.
1. Connect the configuration PC with the LAN.
2. To transfer the project, proceed according to the description in the "Mobile Panels 2nd Generation" operating instructions or in the online help for WinCC (TIA Portal).

Other manuals for Siemens SIMATIC HMI KTP700F Mobile Arctic

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC HMI KTP700F Mobile Arctic and is the answer not in the manual?

Siemens SIMATIC HMI KTP700F Mobile Arctic Specifications

General IconGeneral
BrandSiemens
ModelSIMATIC HMI KTP700F Mobile Arctic
CategoryControl Panel
LanguageEnglish

Related product manuals