Configuring with Web Based Management
6.3 "Wizard" menu
SCALANCE W780/W740 to IEEE 802.11n Web Based Management
Configuration Manual, 08/2018, C79000-G8976-C267-13
103
max. Tx Power
Specify the transmit power of the device. It may be necessary to reduce the transmit
power when using antennas to avoid exceeding the maximum legal transmit power.
Reducing the transmit power effectively reduces cell size
Note
The maximum possible transmit power varies depending on the channel and data rate.
For more detailed information on transmit power, refer to the documentation
"Characteristics radio interfac
e".
Note
If both interfaces of access points with two WLAN interfaces are operated in the same
frequency range, this may cause wireless interference on one or both interfaces at a
transmit power higher than 15 dBm.
Tx power check
Indicates whether the settings that have been made will violate the permitted transmit
power restrictions of the selected country. The following parameters influence this
calculation:
max. Tx Power, Antenna Gain, Additional Attenuation.
The following displays can appear:
Allowed
The channels can be used with the current settings.
Not Allowed (Some Channels)
Among the channels, there are some on which the current transmit power exceeds the
maximum permitted transmit power.
Not Allowed (All Channels)
No permitted operation is possible. The transmit power is too high.
Controlled automatically by iREF
The transmit power is set by the "iREF" function.

Table of Contents

Other manuals for Siemens SIMATIC NET SCALANCE W700

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC NET SCALANCE W700 and is the answer not in the manual?

Siemens SIMATIC NET SCALANCE W700 Specifications

General IconGeneral
BrandSiemens
ModelSIMATIC NET SCALANCE W700
CategoryWireless Access Point
LanguageEnglish

Related product manuals