Security recommendations
SCALANCE W780/W740 to IEEE 802.11n Web Based Management
44 Configuration Manual, 08/2018, C79000-G8976-C267-13
Available protocols per port
The following list provides you with an overview of the open ports on this device.
The table includes the following columns:
Protocol
All protocols that the device supports
Port number
Port number assigned to the protocol
Port status
Open
The port is always open and cannot be closed.
Open (when configured)
The port is open if it has been configured.
Factory setting
Open
The factory setting of the port is "Open".
Closed
The factory setting of the port is "Closed".
Authentication
Specifies whether the protocol authenticates the communications partner during access.
Protocol
Port number
Port status
Factory setting of
the port
Authentication
SSH
TCP/22 Open
(when configured)
Open Yes
TELNET
TCP/23 Open
(when configured)
Open Yes
HTTP
TCP/80 Open
(when configured)
Open Yes
HTTPS
TCP/443 Open
(when configured)
Open Yes
SNTP
NTP
UDP/123 Open
(when configured)
Closed No
SNMP
UDP/161 Open
(when configured)
Open Yes
PROFINET
UDP/34964,
UDP/49154, 49155
Open Open No
Syslog
UDP/514 Open
(when configured)
Open No
EtherNet/IP
TCP/44818,
UDP/2222,44818
Open
(when configured)
Open No

Table of Contents

Other manuals for Siemens SIMATIC NET SCALANCE W700

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC NET SCALANCE W700 and is the answer not in the manual?

Siemens SIMATIC NET SCALANCE W700 Specifications

General IconGeneral
BrandSiemens
ModelSIMATIC NET SCALANCE W700
CategoryWireless Access Point
LanguageEnglish

Related product manuals