EasyManuals Logo

Siemens SIMATIC NET SCALANCE W700 User Manual

Siemens SIMATIC NET SCALANCE W700
456 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #50 background imageLoading...
Page #50 background image
Technical basics
4.2 Interfaces and system functions
SCALANCE W780/W740 to IEEE 802.11n Web Based Management
50 Configuration Manual, 08/2018, C79000-G8976-C267-13
Availability of the system functions
The following table shows the availability of the system functions on the devices. Note that
all functions are described in this configuration manual and in the online help. Depending on
the mode and the KEY-PLUG, some functions are not available.
We reserve the right to make technical changes.
Access point mode
Access points in client
mode.
Client device
Information
Security
Inter AP blocking ✓
W780 iFeatures
(MLFB 6GK5 907-
8PA00)
W700 Security
(MLFB 6GK5907-
0PA00)
-
WLAN
AP overview
✓
-
Client list
✓
-
WDS list
✓
-
AP overlap
✓
-
Force roaming
✓
✓
Client overview
-
✓
Available APs
-
✓
IP assignment
-
✓
Background noise
✓
✓
WLAN statistics
Error
✓
✓
Management sent
✓
✓
Management re-
ceived
✓ ✓
Data sent
✓
✓
Data received
✓
✓
WLAN iFeatures
iREF client list ✓
W780 iFeatures
(MLFB 6GK5 907-
8PA00)
-
iREF WDS list ✓
W780 iFeatures
(MLFB 6GK5 907-
8PA00)
-
AeroScout ✓
W780 iFeatures
(MLFB 6GK5 907-
8PA00)
-
System
PROFINET
✓
-✓
EtherNet/IP
✓
✓

Table of Contents

Other manuals for Siemens SIMATIC NET SCALANCE W700

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC NET SCALANCE W700 and is the answer not in the manual?

Siemens SIMATIC NET SCALANCE W700 Specifications

General IconGeneral
BrandSiemens
ModelSIMATIC NET SCALANCE W700
CategoryWireless Access Point
LanguageEnglish

Related product manuals