Configuring with Web Based Management
6.3 "Wizard" menu
SCALANCE W780/W740 to IEEE 802.11n Web Based Management
96 Configuration Manual, 08/2018, C79000-G8976-C267-13
6.3.1.2
Country Settings
Introduction
On this Basic Wizard page, you configure the country and the system name.
Description
The Basic Wizard page contains the following boxes
Country Code
From this drop-down list, select the country in which the device will be deployed. You do
not need to know the data for the specific country, the channel division and output power
are set by the device according to the country you select.
Note
Locale setting
The correct country setting is mandatory for operation complying with the approvals.
Selecting a country different from the country of use can lead to legal prosecution.
System Name
You can enter the name of the device. If you configure this box, this configuration is
adopted and displayed in the selection area. A maximum of 255 characters are possible.
The system name is also displayed in the CLI input prompt. The number of characters in
the CLI input prompt is limited. The system name is truncated after 16 characters.

Table of Contents

Other manuals for Siemens SIMATIC NET SCALANCE W700

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC NET SCALANCE W700 and is the answer not in the manual?

Siemens SIMATIC NET SCALANCE W700 Specifications

General IconGeneral
BrandSiemens
ModelSIMATIC NET SCALANCE W700
CategoryWireless Access Point
LanguageEnglish

Related product manuals