List of Action Numbers 11/2006
3-850
© Siemens AG, 2006. All rights reserved
SINUMERIK, SIMODRIVE Diagnostics Manual (DA), 11/2006 Edition
No. 104
No. 105
No. 106
No. 107
No. 108
No. 109
Explanation Stopping of a single axis movement by an alarm
Cause The axis is not controlled by the PLC. (exception old reaction with oscillation axis).
Remedy -
Explanation Continuation of a single-axis movement (VDI signal).
Cause The axis has not been stopped previously. Not for all axis types at present.
Remedy -
Explanation Interruption of a single-axis movement (VDI signal).
Cause The axis is not controlled by the PLC. Not for all axis types at present.
Remedy -
Explanation Deletion of distance-to-go of a single-axis movement (VDI signal).
Cause The axis is not controlled by the PLC. Not for all axis types at present.
Remedy -
Explanation Switch on: Axis is now controlled by the PLC (VDI signal).
Cause The axis is not controlled by the PLC. Not for all axis types at present.
Remedy -
Explanation Deactivate: Axis is now controlled by the PLC (VDI signal).
Cause The axis is not controlled by the PLC. Not for all axis types at present.
Remedy -